Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
High-resolution accurate mass- mass spectrometry based- untargeted metabolomics: Reproducibility and detection power
Hanane El Boudlali1, Laura Lehmicke1, Uta Ceglarek1
1Clinical Mass Spectrometry Section, Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, University of Leipzig Medical Center, Liebig Street 27, Leipzig D-04103, Germany.
Abstract:
Untargeted metabolomics aims at the unbiased metabolic profiling and biomarker discovery but requires methods with high sensitivity and reproducibility. Here, we compare three acquisition modes-Data-Dependent Acquisition (DDA), Data-Independent Acquisition (DIA), and AcquireX -to evaluate performance and reproducibility in detecting low-abundance metabolites in a complex matrix. A system suitability test (SST) based on 14 eicosanoid standards was implemented to evaluate the suitability of our instrumental setup prior to conducting untargeted metabolomics analyses and monitor long-term system performance. Bovine liver total Lipid Extract (TLE) was spiked with decreasing levels (10-0.01 ng/mL) of the eicosanoid standard mix (StdMix) to compare the detection power of each mode. Reproducibility was evaluated over three independent measurements, spaced one week apart. Chromatographic separation was performed on a C18-Kinetex Core-Shell column and HRAM-MS/MS data were acquired using an Orbitrap Exploris 480. DIA detected and identified the highest number of metabolic features, (averaging 1036 metabolic features over three measurements), followed by DDA (18 % fewer) and AcquireX (37 % fewer). Moreover, DIA demonstrated superior reproducibility, with a coefficient of variance of 10 % across detected compounds over three measurements, compared to 17 % for DDA and 15 % for AcquireX. DIA further exhibited better compound identification consistency, with 61 % overlap between two days, compared to DDA (43 %) and AcquireX (50 %). DIA reproduced fragmentation spectra patterns with high consistency, contributing to higher reproducibility in compound identification. DIA showed the best detection power for all spiking eicosanoids at 10 and 1 ng/mL in TLE matrix. At low spiking levels, 0.1 and 0.01 ng/mL, a general cut-off was observed for the three acquisition modes. None of this assessed acquisition modes was able to detect and/or identify eicosanoids at physiologically relevant concentrations, explaining their frequent omission in routine untargeted analyses.
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Analyzers: Overview
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...