Related Experiment Video
Updated: Sep 19, 2025

Extraction of Organochlorine Pesticides from Plastic Pellets and Plastic Type Analysis
Published on: July 1, 2017
Plasticizers Analysis in Extractables and Leachables by Gas Chromatography-Mass Spectrometry with Parallel
Jianxin Yu1, Scott Citrowske1, Jacob Strange1
1Abbott Laboratories, Saint Paul, MN 55117, USA.
None:
Plasticizers such as phthalate acid esters including di-(2-ethylhexyl) phthalate (DEHP) and its alternatives are commonly found in extractables and leachables (E&Ls) from plastic-based medical devices. Regulatory agencies require manufacturers to monitor, qualify and quantify the E&Ls from medical devices to ensure the safety. Analyzing E&Ls from medical devices is difficult due to the unpredictability and complexity of matrices. The advent of the novel Polyarc/Flame Ionization Detector (FID), which features compound-independent response, provides the opportunity of quantitation of unknowns-to-be-identified E&Ls without using pure substances for establishing calibration. The present work evaluated firstly the feasibility and efficacy of full scan GC-MS with parallel Polyarc/FID system through analysis of plasticizers in E&Ls. In the same injection, E&Ls were identified by full scan GC-MS, then quantified through Polyarc/FID response factor of internal standards. The results showed that quantitation via response factor from internal standards are more accurate so the need for standards of the identified E&Ls is eliminated. The method can combine screening process and target analysis into a one-step execution, which makes it desirable for E&L analysis. The method was applied to a polyvinyl chloride medical device, yielding 1.183 g/device of acetyl tri-n-butyl citrate, 370.2 mg/device of trioctyltrimellitate, and 3.068 mg/device of DEHP.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Plasticizers
Plasticizers function by using surface-active agents to create repulsive electrostatic forces between cement particles. This dispersion enhances the concrete's...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...