Related Experiment Video
Updated: Sep 19, 2025

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
The Impact of Suctioning on Oxygenation During Rapid Sequence Intubation in the Emergency Department: A Multi-Center
Reuben J Strayer1, Matthew Oliver2, Aaron Chen1
1Department of Emergency Medicine, Maimonides Medical Center, Brooklyn, New York.
Background:
Recent trends in emergency airway management encourage longer periods of suction, and the use of more powerful suction devices. Whether the intensity of oropharyngeal suction during laryngoscopy causes more rapid desaturation is unknown.
Study Objective:
This study aimed to determine whether longer duration of suction leads to more significant desaturation in Emergency Department patients undergoing Rapid Sequence Intubation (RSI).
Methods:
A multicenter pilot randomized controlled trial was conducted at 3 academic tertiary care level 1 trauma centers. Emergency Department patients undergoing RSI and laryngoscopy were randomized to either as needed suction or constant suction. The primary outcome was the decrease in oxygen saturation from the time the laryngoscope blade entered the mouth until endotracheal tube confirmation.
Results:
A total of 76 patients were enrolled (37 in as needed suction, 39 in constant suction). The median absolute drop in saturation was 0% (IQR 0-1) in the as needed suction group and also 0% (IQR 0-0) in the constant group (p = 0.321).
Conclusion:
The study found that constant suctioning during Emergency Department laryngoscopy facilitated by RSI does not cause more rapid desaturation compared to as needed suctioning. However, the reliability of these results is limited by the small sample size and convenience sampling which likely skewed the cohort to patients less likely to develop hypoxia. Further studies are needed to confirm these findings and their implications for emergency airway management.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...

