Related Experiment Video
Updated: Sep 19, 2025

Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Potential Errors in CMAQ NO:NO2 Ratios and Upper Tropospheric NO2 Impacting the Interpretation of TROPOMI Retrievals
Abiola S Lawal1,2, T Nash Skipper1, Cesunica E Ivey2
1School of Civil & Environmental Engineering, Georgia Institute of Technology, 790 Atlantic Drive, Atlanta, Georgia 30332-0355, United States.
Abstract:
Although Chemical Transport Models (CTMs) such as the Community Multiscale Air Quality Model (CMAQ) have been used in linking observations of trace gases to emissions and developing vertical column distributions, there remain consistent biases between CTM simulations and satellite retrievals. Simulated tropospheric NO2 vertical column densities (VCDs) are generally higher over areas with large NO x sources when compared with retrievals, while an opposite bias is found over low NO x regions. Artificial (i.e., numerical) dilution in the model, where emissions are mathematically dispersed uniformly within the originating CTM grid, can impact modeled NO:NO2 ratios, while lower CTM VCD levels often observed over rural areas can be attributed to missing emission sources of NO x or flawed horizontal/vertical transport. Potential causes of both low and high biases are assessed in this study using CMAQ and Tropospheric Monitoring Instrument (TROPOMI) NO2 retrievals. It was found that more detailed modeling of NO x plumes to assess the NO:NO2 ratio in two power plant plumes can mitigate the effect of artificial computational dilution, reducing the bias and overall differences in the observed vs modeled plumes (errors reduced by 30%). Adjustments of upper tropospheric NO2 led to overall improvements, with a reduction in CMAQ bias (-43% to -29%) and improved spatial correlation (0.81 to 0.86). This study highlights the importance of having accurate modeled NO:NO2 ratios when comparing models to retrievals and the impact of unintentional numerical dilution.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Common Leveling Mistakes and Errors
Errors in Global Positioning System
Propagation of Uncertainty from Systematic Error
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Random Error

