Related Experiment Video
Updated: Sep 18, 2025

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Impact of initial direction of Navitor transcatheter heart valve delivery system on final valve orientation and
Hirokazu Miyashita1, Tomoki Ochiai2, Daisuke Sato1
1Department of Cardiology, Shonan Kamakura General Hospital, 1370-1 Okamoto, Kamakura, Kanagawa, 247-8533, Japan.
Abstract:
Data on the impact of the initial Navitor transcatheter heart valve (THV) deployment orientation on the final valve orientation in transcatheter aortic valve implantation (TAVI) assessed using post-implantation computed tomography (CT) is scarce. This study aimed to assess the impact of the initial deployment orientation of Navitor THV on the final orientation and neocommissural overlap with the coronary arteries. Additionally, the incidence of commissural misalignment (CMA) of Navitor THV and its impact on coronary access and short-term valve performance were evaluated. Post-TAVI CT was analysed in 77 patients. Severe coronary artery overlap with THV neocommissure was defined as 0°-20° apart. CMA was categorized by angle deviation from the native commissures: aligned (0°-15°), mild (15°-30°), moderate (30°-45°), and severe (45°-60°). The Navitor delivery system was introduced via the femoral artery with the lock button facing the 3, 6, 9, and 12 o'clock positions. Initial Navitor THV deployment orientation had no impact on the incidence of severe coronary artery overlap. Severe CMA was observed in 80.0% at 3 o'clock, 66.7% at 6 o'clock, 53.8% at 9 o'clock, and 42.2% at 12 o'clock position (p = 0.12). Severe CMA was not associated with the success rate of coronary cannulation after TAVI, short-term valve haemodynamics, or the incidence of hypoattenuated leaflet thickening. Initial Navitor THV orientation did not affect coronary artery overlap or CMA. Moreover, CMA of the Navitor THV did not affect coronary access or short-term valve performance.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization