Performance of polyetheretherketone (PEEK) versus cobalt chromium to fabricate removable partial denture frameworks:
Gunjan Srivastava1, Subrat Kumar Padhiary2, Martin Schimmel3
1Professor, Department of Prosthodontics, Institute of Dental Sciences, Siksha' O' Anusandhan Deemed to be University, Bhubaneswar, India.
Statement Of Problem:
The performance of cobalt chromium (Co-Cr) removable partial dentures (RPDs) is well established, but a comparison with the polyetheretherketone (PEEK) in terms of fit, retention, clinical performance, patient outcomes, and associated complications is lacking.
Purpos:
The purpose of this systematic review was to evaluate the current evidence on the performance of PEEK as a framework or clasp material compared with Co-Cr for the fabrication of RPDs.
Material And Methods:
An electronic search for articles in the English language through PubMed, Scopus, and Web of Science databases from 2000 to 2024 and screened by 2 independent reviewers was made to identify in vitro or clinical studies comparing PEEK with Co-Cr for the fabrication of RPD frameworks and clasps.
Results:
From 327 studies identified, 13 were included: 9 in vitro and 4 clinical studies. Data were extracted regarding the number of participants, types of prosthesis, arch of placement, follow-up period, fit, retention, and patient-reported outcome measures (PROMs). Four of the 9 in vitro studies evaluated the fit of the RPD framework. Five in vitro studies assessed the retention of the prostheses and reported that PEEK demonstrated durability and retention forces comparable with Co-Cr. Four clinical trials compared PROMs and bone loss patterns associated with PEEK and Co-Cr.
Conclusions:
Clinical studies and in vitro research comparing PEEK and Co-Cr frameworks for RPDs are still sparse. However, current evidence indicates a comparable fit with mean ±standard deviation gap distance of 42.8 ±29.4 µm for PEEK frameworks and 130.9 ±50.5 µm for Co-Cr frameworks. Additionally, retention, and patient satisfaction with PEEK frameworks were found similar to those of conventional Co-Cr frameworks.