Related Experiment Video
Updated: Sep 18, 2025

Non-invasive Skeletal Muscle Quantification in Small Animals Using Micro-computed Tomography
Published on: November 8, 2024
Comparative Analysis of Ultrasonography and MicroCT Imaging for Organ Size Evaluation in Mice
Juan Jose Jimenez Catalan1, Marina Ferrer Clotas2, Juan Antonio Camara Serrano3
1Preclinical Imaging Platform, Vall d'Hebron Institute of Oncology, 08035 Barcelona, Spain.
Abstract:
In this work, the authors compared microCT and in vivo ultrasonography in terms of accuracy and efficacy for measuring the volume of various organs in mice. Two quantification protocols were applied: ellipsoidal volume measuring maximum diameters in all three axes in both imaging systems and manual delineation of organ borders in microCT studies. The results were compared with ex vivo volumes. In general, both imaging techniques and quantification protocols are accurate, but ultrasound is faster in both acquisition and analysis. The only accurate method for heart volume measurement is manual segmentation on microCT. For the ovary, none of the techniques and protocols had a positive correlation with ex vivo volume. The three-diameter method can be used for ellipsoid organs because of its rapidity, but for more irregular structures, manual segmentation is recommended, although it is time-consuming.
More Related Videos
03:41High-Resolution Ultrasonography for the Analysis of Orthotopic ATC Tumors in a Genetically Engineered Mouse Model
Published on: October 11, 2022
07:44Non-Invasive Ultrasound Assessment of Endometrial Cancer Progression in Pax8-Directed Deletion of the Tumor Suppressors Arid1a and Pten in Mice
Published on: February 17, 2023