Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

2.5K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.5K
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

937
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
937
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

1.5K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.5K
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

636
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
636
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

1.7K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.7K
Special considerations while measuring blood pressure01:28

Special considerations while measuring blood pressure

828
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
828

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The Rise in Homemade Sunscreen Trends and Future Impacts on Skin Cancer Risk: Systematic Review.

JMIR dermatology·2026
Same author

Threat of Melee-related Terrorist Attacks: A Retrospective Analysis of Patterns, Mortality, and Public Health Impact.

Disaster medicine and public health preparedness·2026
Same author

Exploring the Association of Systolic Blood Pressure and Intracranial Pressure Variability and Subarachnoid Hemorrhage Patient Outcomes.

Journal of clinical medicine·2026
Same author

Does 6.7% Reflect Reality? Response to "Precipitated Withdrawal Following Emergency Department-initiated Buprenorphine: A Retrospective Study".

Journal of addiction medicine·2026
Same author

The authors' responses: "Reader comment regarding prophylactic antibiotics for immunosuppressed individuals with anterior nasal packing: A propensity score matching study".

The American journal of emergency medicine·2026
Same author

Routine chest X-ray in atraumatic chest pain with normal vital signs: A propensity-matched TriNetX analysis.

The American journal of emergency medicine·2026

Related Experiment Video

Updated: Sep 18, 2025

Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
06:51

Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research

Published on: October 20, 2023

1.2K

Emergency Department Blood Pressure Management in Type B Aortic Dissection: An Analysis with Machine Learning.

Nelson Chen1, Jessica V Downing2,3, Jacob Epstein4

  • 1University of Maryland School of Medicine, Baltimore, Maryland.

The Western Journal of Emergency Medicine
|June 25, 2025
PubMed
Summary

Strict blood pressure and heart rate control in acute aortic dissection is challenging in the emergency department. Higher initial vital signs and less pain management were associated with failure to meet American Heart Association (AHA) guidelines.

More Related Videos

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
06:26

Novel and Innovative Hybrid Technique for Type A Aortic Dissection

Published on: March 28, 2025

499
Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
08:12

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS

Published on: November 26, 2018

10.2K

Related Experiment Videos

Last Updated: Sep 18, 2025

Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
06:51

Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research

Published on: October 20, 2023

1.2K
Novel and Innovative Hybrid Technique for Type A Aortic Dissection
06:26

Novel and Innovative Hybrid Technique for Type A Aortic Dissection

Published on: March 28, 2025

499
Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
08:12

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS

Published on: November 26, 2018

10.2K

Area of Science:

  • Cardiology
  • Emergency Medicine
  • Medical Informatics

Background:

  • Acute aortic dissections (AAD) carry significant morbidity and mortality.
  • American Heart Association (AHA) guidelines recommend strict systolic blood pressure (SBP) and heart rate (HR) control for type B AAD.
  • Predictors for successful emergency department (ED) SBP management in type B AAD are not well-established.

Purpose of the Study:

  • To identify predictors of achieving SBP and HR goals in patients with type B AAD in the ED.
  • To evaluate adherence to AHA guidelines for hemodynamic management prior to transfer.

Main Methods:

  • Retrospective analysis of 134 adult patients with type B AAD transferred between 2017-2020.
  • Inclusion criteria: initial SBP >120 mmHg and HR >60 bpm.
  • Random forest (RF) algorithms used to predict achievement of SBP <120 mmHg and HR <60/80 bpm.

Main Results:

  • Only 19% of patients achieved SBP <120 mmHg at ED departure.
  • Higher triage SBP and intravenous labetalol predicted SBP >120 mmHg, contradicting AHA guidelines.
  • Adequate pain management and timely CT scans predicted achievement of HR goals.

Conclusions:

  • Many type B AAD patients do not meet AHA hemodynamic goals in the ED before transfer.
  • Higher initial SBP and HR predict failure to achieve therapeutic goals.
  • Effective pain management may contribute to meeting HR targets.