Related Experiment Video
Updated: Sep 18, 2025

Extraction and Characterization of Surfactants from Atmospheric Aerosols
Published on: April 21, 2017
Centrifuge-Less Mixed Micelle-Mediated Cloud Point Extraction-Spectrophotometric Determination of Vanadium Using
Andrea Gajdošová1, Petya Racheva2, Denitsa Kiradzhiyska2
1Department of Analytical Chemistry, Institute of Chemistry, Pavol Jozef Šafárik University in Košice, SK-04154 Košice, Slovakia.
Abstract:
A novel, environmentally friendly cloud point extraction (CPE) method based on 4-nitrocatechol (H2L) was developed in this study to spectrophotometrically determine trace vanadium. This method utilizes a mixed micelle-mediated system comprising a cationic surfactant (cetylpyridinium chloride, CPC) and a nonionic surfactant (Triton X-114). In contrast to conventional CPE, the present approach does not employ centrifugation to separate the two phases. The distinguishing characteristic of the extracted species, (CP+)[VVOL2], is its ability to absorb light across the entire visible spectrum. The measurement at 670 nm, where the complex displays a local maximum, is advantageous for two primary reasons. Firstly, the blank exhibits virtually no absorption, a property that engenders stable and reproducible results. Secondly, selectivity is high because almost all other metal complexes have absorption bands at shorter wavelengths. The proposed method has the following characteristics: a linear range of 2-305 ng mL-1, a limit of detection of 0.6 ng mL-1, a molar absorptivity coefficient of 1.22 × 105 M-1 cm-1, a Sandell sensitivity of 0.42 ng cm-2, and a blue applicability grade index (BAGI) of 67.5. Its efficacy was demonstrated in the analysis of mineral water, a spent vanadium-containing catalyst, and a dietary supplement.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Extraction: Advanced Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Qualitative Analysis
For instance, group IV...
Precipitation Titration: Overview
A precipitation titration curve demonstrates the change in concentration of the titrant or analyte upon adding the...
Colloidal precipitates

