Related Experiment Video
Updated: May 2, 2026

11:20
Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses
Published on: July 2, 2012
16.9K
The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source. Corrigendum.
Peter Walter1, Timur Osipov1, Ming Fu Lin1
1SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA.
Journal of Synchrotron Radiation
|June 26, 2025
Summary
A correction has been made to the author list in a 2022 journal article. This ensures accurate attribution for the published scientific research.
Area of Science:
- Scientific Publishing
- Research Integrity
Context:
- A previous publication by Walter et al. (2022) in J. Synchrotron Rad. contained an error in the author list.
Purpose:
- To correct an error in the author attribution of a published scientific article.
- To maintain the accuracy and integrity of scientific records.
Summary:
- The name of an author in the article 'Walter et al. (2022) [J. Synchrotron Rad. 29, 957-968]' has been officially corrected.
- This correction ensures proper acknowledgment of all contributors.
Impact:
- Upholds the standards of scientific accuracy and authorship.
- Provides a corrected reference for future citations and research.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
993
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
993
Mass Analyzers: Overview
2.0K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
2.0K
Atomic Absorption Spectroscopy: Instrumentation
2.1K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
2.1K
Atomic Absorption Spectroscopy: Radiation and Light Sources
1.6K
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
1.6K
Atomic Emission Spectroscopy: Instrumentation
1.5K
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
1.5K
Atomic Emission Spectroscopy: Interference
785
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
785

