Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Measurement of Blood Pressure01:17

Measurement of Blood Pressure

1.5K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.5K
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

707
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
707
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

927
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
927
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

635
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
635
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

1.7K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Continuous Cuffless Blood Pressure Estimation Based on Fractional Order Derivatives via Gramian Angular Field Only Using Photoplethysmograms.

IET systems biology·2025
Same author

Multi-Party Verifiably Collaborative Encryption for Biomedical Signals via Singular Spectrum Analysis-Based Chaotic Filter Bank Networks.

Sensors (Basel, Switzerland)·2025
Same author

AMFF-Net: An Effective 3D Object Detector Based on Attention and Multi-Scale Feature Fusion.

Sensors (Basel, Switzerland)·2023
Same author

Fusion of various optimisation based feature smoothing methods for wearable and non-invasive blood glucose estimation.

IET systems biology·2023
Same author

Classification Approach for Attention Assessment via Singular Spectrum Analysis Based on Single-Channel Electroencephalograms.

Sensors (Basel, Switzerland)·2023
Same author

Deep Learning-Based Synthesized View Quality Enhancement with DIBR Distortion Mask Prediction Using Synthetic Images.

Sensors (Basel, Switzerland)·2022

Related Experiment Video

Updated: Sep 18, 2025

Simple Continuous Glucose Monitoring in Freely Moving Mice
03:25

Simple Continuous Glucose Monitoring in Freely Moving Mice

Published on: February 24, 2023

6.1K

Principal Component Analysis Based Quaternion-Valued Medians for Non-Invasive Blood Glucose Estimation.

Jingheng Feng1, Bingo Wing-Kuen Ling1

  • 1School of Information Engineering, Guangdong University of Technology, Guangzhou 510006, China.

Sensors (Basel, Switzerland)
|June 27, 2025
PubMed
Summary

This study introduces a novel method using denoised quaternion-valued medians from photoplethysmograms (PPGs) for accurate, non-invasive blood glucose estimation. The approach effectively fuses four-channel PPG data, outperforming traditional methods.

Keywords:
non-invasive blood glucose estimationprincipal components analysisquaternion-valued median

More Related Videos

A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli
08:01

A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli

Published on: August 12, 2016

9.1K
Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
15:18

Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research

Published on: January 12, 2013

16.5K

Related Experiment Videos

Last Updated: Sep 18, 2025

Simple Continuous Glucose Monitoring in Freely Moving Mice
03:25

Simple Continuous Glucose Monitoring in Freely Moving Mice

Published on: February 24, 2023

6.1K
A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli
08:01

A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli

Published on: August 12, 2016

9.1K
Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
15:18

Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research

Published on: January 12, 2013

16.5K

Area of Science:

  • Biomedical Engineering
  • Signal Processing

Background:

  • Non-invasive blood glucose estimation is crucial for diabetes management.
  • Photoplethysmograms (PPGs) offer a potential non-invasive method, but are susceptible to noise.
  • Existing methods often process PPG channels independently, potentially missing inter-channel relationships.

Purpose of the Study:

  • To develop an improved feature extraction and denoising technique for non-invasive blood glucose estimation using four-channel PPGs.
  • To leverage quaternion-valued medians and principal component analysis (PCA) for enhanced feature representation.
  • To validate the proposed method's effectiveness and robustness against existing approaches.

Main Methods:

  • Utilized quaternion-valued medians as initial features from four-channel PPG signals.
  • Applied principal component analysis (PCA) for denoising by fusing information across all four channels.
  • Employed a random forest classifier for blood glucose level (BGL) estimation using the denoised features.

Main Results:

  • The proposed PCA-based quaternion-valued medians significantly outperformed traditional denoising and feature extraction methods.
  • Fusion of four-channel PPG data effectively exploited inter-channel relationships, leading to improved estimation accuracy.
  • The method demonstrated effectiveness and robustness across two independent datasets.

Conclusions:

  • PCA-based denoising of quaternion-valued medians provides a robust and effective approach for non-invasive BGL estimation.
  • Fusing multi-channel PPG data enhances feature extraction for improved biomedical signal analysis.
  • This technique offers a promising advancement for non-invasive glucose monitoring in diabetes care.