Related Experiment Video
Updated: Sep 17, 2025

Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System
Published on: July 11, 2025
Improving radiology reporting accuracy: use of GPT-4 to reduce errors in reports
Connor J Mayes1, Chloe Reyes2, Mia E Truman3
1Mayo Clinic College of Medicine and Science, Phoenix, USA.
Purpose:
Radiology reports are essential for communicating imaging findings to guide diagnosis and treatment. Although most radiology reports are accurate, errors can occur in the final reports due to high workloads, use of dictation software, and human error. Advanced artificial intelligence models, such as GPT-4, show potential as tools to improve report accuracy. This retrospective study evaluated how GPT-4 performed in detecting and correcting errors in finalized radiology reports in real-world settings for abdominopelvic computed tomography (CT) reports.
Methods:
We evaluated finalized CT abdominopelvic reports from a tertiary health system by using GPT-4 with zero-shot learning techniques. Six radiologists each reviewed 100 of their finalized reports (randomly selected), evaluating GPT-4's suggested revisions for agreement, acceptance, and clinical impact. The radiologists' responses were compared by years in practice and sex.
Results:
GPT-4 identified issues and suggested revisions for 91% of the 600 reports; most revisions addressed grammar (74%). The radiologists agreed with 27% of the revisions and accepted 23%. Most revisions were rated as having no (44%) or low (46%) clinical impact. Potential harm was rare (8%), with only 2 cases of potentially severe harm. Radiologists with less experience (≤ 7 years of practice) were more likely to agree with the revisions suggested by GPT-4 than those with more experience (34% vs. 20%, P = .003) and accepted a greater percentage of the revisions (32% vs. 15%, P = .003).
Conclusions:
Although GPT-4 showed promise in identifying errors and improving the clarity of finalized radiology reports, most errors were categorized as minor, with no or low clinical impact. Collectively, the radiologists accepted 23% of the suggested revisions in their finalized reports. This study highlights the potential of GPT-4 as a prospective tool for radiology reporting, with further refinement needed for consistent use in clinical practice.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...