Related Experiment Video
Updated: Sep 17, 2025

A Protocol of Manual Tests to Measure Sensation and Pain in Humans
Published on: December 19, 2016
Comparison of laboratory results and pain perception in self-sampled capillary blood versus venous blood sampling: a
Dominik Schröder1, Angelika Hafke2, Eva Hummers1
1Department of General Practice University Medical Center Göttingen, Göttingen, Germany.
Abstract:
Blood sampling is an essential part of medical diagnostics and treatment. Recent advances in capillary blood self-collection (BSC) devices offer promising alternatives to traditional venipuncture. However, the concordance between laboratory results from self-collected capillary samples and the gold standard venous collection requires systematic evaluation before clinical implementation. We conducted a systematic review and meta-analysis comparing laboratory results and pain perception between self-collected capillary and venous blood samples. From 1,436 identified studies, 26 met the inclusion criteria. The overall correlation between capillary BSC and venous samples was strong (r = 0.89, 95 % CI: 0.86-0.92) with high heterogeneity (I2 = 94.2 %). For dichotomous outcomes, concordance was excellent (0.99, 95 % CI: 0.98-1.00). Capillary BSC was associated with significantly lower pain scores than venipuncture (SMD = -0.65, 95 % CI = -0.96; -0.35), with upper arm devices having lower pain scores compared to fingerprick methods. Despite methodological heterogeneity, capillary BSC shows strong agreement with venous sampling for most lab parameters and reduces patient discomfort. It appears especially promising for chronic disease monitoring, patients with difficult venous access, and resource-limited settings. Future studies should standardize collection protocols, assess clinical outcomes, and analyze cost-effectiveness. Although no included study showed improved disease management or cost benefits, broader BSC use may enhance healthcare accessibility while maintaining diagnostic accuracy.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation