Related Experiment Video
Updated: Sep 17, 2025

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
Reproducibility of circumferential strain on cine displacement encoding with stimulated echoes magnetic resonance
Siyue Li1, Shu-Fu Shih1, Arutyun Pogosyan2
1Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.
Background:
Magnetic resonance imaging (MRI) with displacement encoding with stimulated echoes (DENSE) is well recognized for accurate and precise quantification of myocardial displacement and strain, but its reproducibility before and after contrast injection has not been investigated. Gadolinium is the most widely used contrast agent. Ferumoxytol is increasingly used off-label in specific patient groups. We aim to assess the reproducibility of cine DENSE MRI to measure global and segmental circumferential myocardial strain (ECC) before and after contrast injection for gadolinium and ferumoxytol, respectively.
Methods:
All imaging was conducted using 3T scanners. In 11 patients with cardiac disease, breath-hold two-dimensional cine DENSE was acquired in a mid-ventricular short-axis slice before and following the injection of gadolinium (0.1 mmol/kg). A separate cohort of 11 subjects (5 healthy subjects and 6 patients with ischemic heart disease) received 3 incremental doses of ferumoxytol: 0.125, 1.875, and 2.0 mg/kg (to a cumulative dose of 4.0 mg/kg). The same DENSE acquisition was performed before and after each incremental dose. Post-processing generated left ventricular (LV) displacement and ECC maps, and strain-time curves. Global and segmental ECC in six mid-level short-axis LV segments were compared. Signal-to-noise (SNR) was evaluated on the magnitude images throughout the cardiac cycle in the myocardium, liver, and back muscle, respectively. A Bayesian analysis was performed to test results with region of practical equivalence (ROPE) at ±5 for SNR and ±0.02 for ECC (p < 0.05 as significant).
Results:
Based on the percentage within the ROPE and the corresponding p-values, global ECC exhibited excellent practical equivalence under pre- and post-contrast conditions for gadolinium (p = 0.413) and ferumoxytol (p ≥ 0.161). Segmental ECC reproducibility was consistently high across all comparative analyses, with at least 87.02% falling within the ROPE. Gadolinium administration significantly improved SNR in all tissues during the early systolic phases (1-5, p ≤ 0.021). Ferumoxytol resulted in a reduction in liver SNR during diastolic phases (10-20, p ≤ 0.011) and a significant increase in myocardium SNR during systolic phases (1-5, p ≤ 0.034).
Conclusion:
Good reproducibility of global and segmental ECC measurements using cine DENSE before and after contrast injection is achievable at 3T.
More Related Videos
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging

