Enhanced ventricular synchrony and myocardial function with bipolar left bundle area pacing: a comparative study of
Jeng-Yu Jan1, Kuo-Li Pan1, Pei-Chun Yeh1
1Division of Cardiology, Chiayi Chang Gung Memorial Hospital, No. 6, West Section, Jiapu Road, Puzi City, Chiayi County 61363, Taiwan.
Aims:
Cardiac pacing aims to replicate physiological heart rhythm. While left bundle area pacing (LBAP) enhances left ventricular (LV) activation, it often struggles to fully address interventricular dyssynchrony. Bipolar LBAP with anodal ring capture (LBAP-ARC) offers a potential solution by synchronously activating both left and right bundle branches. This study aims to compare the effects of unipolar LBAP and LBAP-ARC on ventricular synchrony and myocardial function.
Methods And Results:
A prospective cohort study was conducted with enroling 32 patients undergoing successful LBAP implantation. Pacing thresholds, lead impedance, QRS duration, and echocardiographic parameters-including LV and right ventricular (RV) global longitudinal strain (GLS), systolic dyssynchrony index, and interventricular mechanical delay (IVMD)-were assessed under unipolar LBAP and LBAP-ARC configurations. Left bundle area pacing with anodal ring capture significantly improved LV GLS (-16.09% vs. -14.85%, P = 0.0006) and reduced IVMD (5.13 ms vs. 21.76 ms, P < 0.0001) compared to unipolar LBAP at 1-week follow-up, and these improvements persisted at 3 months (-16.70% vs. -14.98%, P = 0.0005 for LV GLS; 8.01 ms vs. 21.75 ms, P = 0.0045 for IVMD). Subgroup analysis showed enhanced LV (-16.47% vs. -14.76%, P = 0.0094) and RV GLS (-16.24% vs. -15.86%, P = 0.0344) in patients with biphasic QRS patterns in leads II/III. Improvements in RV GLS were less pronounced in patients with predominantly positive QRS patterns in leads II/III.
Conclusion:
Left bundle area pacing with anodal ring capture enhances ventricular synchrony and improves subclinical myocardial function compared to unipolar LBAP, establishing itself as a promising approach in physiological cardiac pacing.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Mechanism of Cardiac Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...