Related Experiment Video
Updated: Sep 17, 2025

Fabrication of a Bioactive, PCL-based "Self-fitting" Shape Memory Polymer Scaffold
Published on: October 23, 2015
Volumetric stability of biphasic hap/β-tcp/collagen implants in malar augmentation: A CBCT-Based case series after
Martins Lauskis1, Oskars Radzins2, Sergio E Uribe3
1Department of Oral and Maxillofacial Surgery and Oral Medicine, Riga Stradins University, Riga, Latvia; Institute of Stomatology, Riga Stradins University, Riga, Latvia.
Objective:
Evaluate volumetric stability and symmetry of Biphasic Hydroxyapatite (HAp)/β-Tricalcium phosphate (β-TCP)/collagen (BCP-collagen) implants in malar augmentation post-orthognathic surgery over one year using Cone-Beam-CT (CBCT) and explore influencing factors.
Methods:
Retrospective case-series analysis of 45 patients (38 females) who underwent bimaxillary orthognathic surgery with malar augmentation using BCP-collagen implants. CBCT scans were taken at 1 week, 4 months, and 12 months post-surgery. Regression analysis explored potential factors influencing volume loss, including age and sex (p < 0.05).
Results:
Median patient-age was 26 years (IQR: 22-32). One week postoperatively, median implant-volume was 1356.70 mm3 (SD = 5888.53). By four-months, it decreased to 985.46 mm3 (SD = 4352.47), a 25.4 % reduction (p < 0.001). Afterwards, a 1.3 % volume decrease (p = 0.42). Volume loss varied between 35.1 and 14.7 %. Asymmetry >7 % was observed in 17.7 % of patients. No significant differences in volume loss were found between sexes (p = 0.6) or age groups (p > 0.9). Regression showed no significant associations with age (β = 0.02, 95 %CI: -0.48, 0.53, p > 0.9) or sex (β = 11, 95 %CI: -30, 52, p = 0.6).
Conclusion:
BCP-collagen implants exhibit early volume loss but stabilise long-term. High variability and asymmetry in volumetric changes challenge standard overcorrection strategies, emphasising the need for early monitoring. CBCT enables precise volumetric assessment and may improve surgical decision-making.