Comprehensive analysis of temperature distribution in OPGW cable considering ramifications of short circuit current

Ahsan Ashfaq1,2, Umair Khalique3,4, Akif Nadeem5

  • 1College of Intelligent Manufacturing and Digital Mining, Yuncheng Vocational and Technical University, Yuncheng, 044000, China. ahsan.xjtu@gmail.com.

Scientific Reports
|July 2, 2025
PubMed

Related Concept Videos

Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Cable Subjected to Its Own Weight01:13

Cable Subjected to Its Own Weight

Overhead power transmission lines rely on cables to carry electricity across large distances. To ensure the stability and functionality of these lines, it is crucial to understand the shape and tension experienced by the cables under the influence of their weight.
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
542
Cable Subjected to a Distributed Load01:24

Cable Subjected to a Distributed Load

The analysis of suspension bridges is a complex and critical process that involves multiple factors, including the shape and tension of the main cables. The main cables of suspension bridges are subjected to distributed loads, which result in changes in tensile forces and deformation of the cable. These loads must be carefully considered to ensure that the bridge is safe and capable of supporting the weight of different loads.
813
Energy Stored In A Coaxial Cable01:31

Energy Stored In A Coaxial Cable

A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
1.7K
Kirchhoff's Current Law01:04

Kirchhoff's Current Law

In the realm of electrical engineering, physicist Gustav Robert Kirchhoff made a significant contribution in 1847 by introducing Kirchhoff's laws for electric circuit analysis. These laws, particularly Kirchhoff's Current Law (KCL), have become foundational principles in understanding and analyzing electrical circuits.
Kirchhoff's Current Law is based on the principle of charge conservation. It states that at any node (a point where two or more circuit elements meet) in an...
1.4K
Power Dissipated in a Circuit: Problem Solving01:15

Power Dissipated in a Circuit: Problem Solving

The equivalent resistance of a combination of resistors depends on their values and how they are connected.
The simplest combinations of resistors are series and parallel connections. In a series circuit, the first resistor's output current flows into the second resistor's input; therefore, each resistor's current is the same. Thus, the equivalent resistance is the algebraic sum of the resistances. The current through the circuit can be found from Ohm's law and is equal to the...
1.2K