Nour Alhuda Alaghawani1, Abrar Mohamed1, Ahmed Makhlouf2
1College of Pharmacy, QU Health, Qatar University, Doha, Qatar.
Background:
Paramedics working in emergency medical services (EMS) routinely administer life-saving medications to patients under urgent conditions. However, these medications are frequently subjected to undocumented fluctuations in environmental conditions, particularly temperature and humidity, which may lead to drug degradation and potentially compromise patient safety. In countries like the State of Qatar, known for its elevated temperatures and humidity, the environmental exposure of EMS medications stored in rapid response cars (RRCs) has not yet been systematically assessed. In this study, we aimed to evaluate the fluctuations in temperature and humidity experienced by ambulatory medications over a 12-month period.
Methods:
Six RRCs, each with three temperature and humidity loggers were utilized to collect real-life environmental data. Two loggers were placed in two paramedic bags stored at the back of the RRCs while a third logger was attached in the middle inside each car. Temperature and humidity readings were recorded at 10-minute intervals over 12 months for assessment. Data was then extracted using ElitechLog software, visualized using Python, and statistically analyzed. The mean kinetic temperature (MKT) was also calculated.
Results:
Temperature values reached 59.1 and 65.7 °C in the bags and inside the RRC, respectively. The MKT exceeded the United States Pharmacopeia recommendations of 30 °C, and in some instances, it exceeded 50 °C. Little to no difference was observed between the two bags in each car however, greater temperature values and MKT violations were reported by the centrally located sensor inside the RRCs.
Conclusion:
The reported MKT violations highlight the need to develop and implement improved storage strategies for EMS medications in emergency vehicles operating in extremely hot climates. However, given that medication bags are frequently exposed to high ambient temperatures when carried outside by paramedics, storage solutions alone are insufficient to fully prevent deviations from manufacturers' recommended conditions. This underscores the importance of specialized training for paramedics on stringent medication handling protocols to minimize temperature exposure and ensure drug safety and efficacy.
Clinical Trial Number:
Not applicable.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...