CASE REPORT: TO STOP ON TIME - ONE OF THE HARDEST DECISIONS: 'LOSS' OF THE STENT IN A CALCIFIED RCA
Ivan Rosović1, Damir Avdagić1, Rajko Miškulin1
1Thalassotherapia Opatija - Clinic for rehabilitation, treatment and prevention of heart and blood vessels diseases.
Insights
This case report details a challenging percutaneous coronary intervention (PCI) in a highly calcified right coronary artery. Rotablation was crucial for successful stent implantation after initial predilation failed.
Area of Science:
- Interventional Cardiology
- Cardiovascular Imaging
- Vascular Biology
Background:
- Coronary artery disease (CAD) management often involves percutaneous coronary intervention (PCI).
- Heavily calcified lesions pose significant technical challenges during PCI.
- Accurate assessment of stenosis significance, including fractional flow reserve (FFR), is critical.
Abstract:
A case report of a 63-year-old man who was indicated for invasive coronarography during outpatient treatment. The completed coronarography confirmed a significant stenosis in the highly calcified right coronary artery (RCA). In order to determine the hemodynamic significance of the borderline significant stenosis of the curved branch of the left coronary artery, FFR was performed. Despite the use of non-compliance balloons and high-pressure OPN balloons during elective PCI-RCA, the lesion in question could not be predilated, resulting in the need for the patient to undergo PCI-RCA with rotablation. During the repeated PCI-RCA procedure, the proximal and middle segments were subjected to rotablation. Non-compliant balloon catheters were used to perform a successful predilatation of the middle segment lesion and to try to place a stent in the designated lesion. Due to the calcified curve of the proximal segment, the stent was unable to pass through while being retracted into the leading catheter, causing it to fall into the proximal segment. The stent balloon was used to push the stent and insert it into the curve between the proximal and middle segment. A small balloon catheter (1.2 x 15 mm) successfully passed through the unexpanded stent. After subsequent inflating of the small balloon catheter and further inflating of larger balloons the lost stent was fully expanded and implanted with optimal control coronarography findings.
More Related Videos
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Coronary Artery Disease V: Interprofessional Care
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome I: Introduction
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Cardiac Catheterization I: Pre-Procedure Overview