Continuous assessment of tissue perfusion using quantitative indocyanine green fluorescence imaging during controlled
Frederik Thørholm Andersen1, Jacob Petersen2,3, Alexander Emil Kaspersen2
1Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 69, 8200, Aarhus N, Denmark. fta@clin.au.dk.
Background:
Indocyanine green fluorescence imaging (ICG-FI) is a novel tool for continuous assessment of tissue perfusion. However, consensus on the optimal methodology is lacking. It was hypothesized that quantitative ICG-FI parameters based on continuous micro-dosing correlate with corresponding transit time flow measurements in the functional renal end artery. This study aimed to examine the feasibility of continuous, quantitative ICG-FI for detecting perfusion changes (hypoperfusion, reperfusion) in porcine kidneys.
Methods:
Renal perfusion was assessed using continuous, quantitative ICG-FI under controlled renal artery flow adjustments (no, partial, full, partial, and no occlusion) in ten healthy female pigs. Four 0.008 mg/kg ICG micro-doses were administered with 60-s intervals for each flow adjustment. As a reference, simultaneous renal artery transit time flow probe measurements were recorded. ICG-FI parameters were extracted by PerfusionWorks®, providing surrogate markers for perfusion, and correlated to the reference renal artery transit time flow measurements using linear regression modeling.
Results:
During hypoperfusion, mean flow decreased from 277 to 139 to 0 ml/min in the no, partial, and full occlusion steps, respectively. Fingress (R2 = 79%), Fmax (R2 = 79%), and slope (R2 = 78%) correlated with flow. During reperfusion, mean flows increased from 0 to 169 to 240 ml/min in the full, partial, and no occlusion steps, respectively, and Fingress (R2 = 71%), Fmax (R2 = 69%), and slope (R2 = 79%) also correlated with flow. Overall, slope exhibited the strongest correlation (R2 = 54%). Tingress, T½max, time ratio, and Tmax exhibited poor correlations with flow.
Conclusion:
Continuous assessment of renal perfusion was technically feasible. In this kidney model, the combined ICG-FI parameter, slope, and the intensity-dependent parameters Fingress and Fmax exhibited convincing correlation with flow, appearing promising for the continuous assessment of tissue perfusion. Time-related parameters did not correlate with flow in this specific model, likely due to the kidney's unique vascular characteristics.
More Related Videos
04:01Indocyanine Green-Guided Intraoperative Imaging to Facilitate Video-Assisted Retroperitoneal Debridement for Treating Acute Necrotizing Pancreatitis
Published on: September 8, 2022
03:27The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025