Optimizing data analysis for broadband mid-infrared absorption spectroscopy: A hybrid dataset approach
Roderik Krebbers1, Laurens A Æ Sluijterman2, Joris Meurs1
1Life Science Trace Detection Laboratory, Department of Analytical Chemistry & Chemometrics, Institute for Molecules and Materials, Radboud University, Heyendaalseweg 135, 6525 AJ, Nijmegen, the Netherlands.
Background:
Broadband mid-infrared spectroscopy for gas sensing is a rapidly progressing field with a main frontier in novel mid-infrared ultra-broadband laser sources. These sources provide increasingly complex and high-resolution spectra that are useful for highly sensitive multispecies (trace) gas detection. However, laser-based sources also add a high level of instrument-specific noise and baseline drifts. To efficiently handle the complexity of data and simultaneously overcome the noise and baseline drift, a demand arises to assess and enhance the processing of the acquired spectra.
Results:
We present a simulation-based approach that improves the detection of gas compounds from broadband mid-infrared spectra. The central idea is to construct a realistic simulation environment in which the data processing of any model of choice can be improved. This can benefit both commonly used processing techniques, such as classical least squares (CLS) fitting, which can be fine-tuned, and statistical models such as partial least squares (PLS), which demand a (relatively) large realistic training set. In addition, we can estimate an instrument- and application-specific detection limit a priori. The simulated spectra are made by combining simulated absorbance spectra with measured (featureless) background intensity spectra, which is crucial to incorporate instrument-specific effects such as baseline drifts. The resulting hybrid dataset is scalable in size and complexity. The workflow was applied to real-life measurements in the 8-11 μm wavelength region to detect trace levels of acetone in CO2- and water vapor-rich exhaled human breath samples. Both CLS and PLS models could be considerably improved by using our proposed approach.
Significance:
The workflow presented here provides a means to optimize, train, and assess data-processing techniques for broadband mid-infrared gas spectra. The approach is widely applicable: it can be implemented for any gas absorption spectroscopic instrument with broadband coverage, as long as it is possible to determine the instrument-specific characteristics, and it can improve and evaluate a wide variety of data-processing techniques.
More Related Videos
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
11:05High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
Related Concept Videos
Applications of IR Spectroscopy: Overview
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Absorption Frequency: Hybridization
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...