Effects of incoming polygonal fault systems on subduction zone and slow slip behavior

Maomao Wang1, Philip M Barnes2, Demian Saffer3

  • 1College of Oceanography, Hohai University, Nanjing, Jiangsu, China.

Science Advances
|July 4, 2025
PubMed

Related Concept Videos

Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
130
Plastic Behavior01:21

Plastic Behavior

A material's elastic behavior is characterized by the disappearance of stress once the load is removed, allowing the material to return to its original state. However, when stress surpasses the yield point, yielding commences, marking the onset of plastic deformation or permanent set. This change from elastic to plastic behavior is influenced by the peak stress value and the duration before the load is removed. An intriguing observation occurs when a specimen is loaded, unloaded, and...
270
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
150
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
182
Rolling With Slipping01:14

Rolling With Slipping

Rolling with slipping is a physical phenomenon that occurs when a rolling object experiences both rotational and linear motion but also experiences frictional forces that cause slipping. This phenomenon can occur in various situations, such as when a tire rolls on a wet road or a ball rolls on a rough surface.
An object's rolling motion is characterized by its rotation around its axis, while linear motion refers to the object's translational motion along a surface. Frictional forces can...
5.7K
Translesion DNA Polymerases02:10

Translesion DNA Polymerases

Translesion (TLS) polymerases rescue stalled DNA polymerases at sites of damaged bases by replacing the replicative polymerase and installing a nucleotide across the damaged site. Doing so, TLS allows additional time for the cell to repair the damage before resuming regular DNA replication.
TLS polymerases are found in all three domains of life - archaea, bacteria, and eukaryotes. Of the different classes of TLS polymerases, members of the Y family are fitted with specialized structures that...
10.2K