Early and Midterm Outcomes of INSPIRIS RESILIA Versus AVALUS: A Propensity Score Matching Analysis
Takuya Narita1, Taisuke Nakayama2, Shuhei Nishijima3
1Cardiovascular Surgery, Chiba-Nishi General Hospital, Matsudo, Chiba, Japan; Cardiovascular Surgery, Yokohama Rosai Hospital, Yokohama, Kanagawa, Japan.
The INSPIRIS RESILIA bioprosthesis and AVALUS bioprosthesis show similar survival and major adverse cardiovascular event rates after aortic valve replacement. Both bioprosthetic valves offer comparable early and midterm clinical outcomes in patients undergoing AVR.
Area of Science:
- Cardiovascular Surgery
- Bioprosthetic Heart Valves
- Aortic Valve Replacement
Background:
- Aortic valve replacement (AVR) is a critical procedure for managing aortic valve disease.
- Bioprosthetic valves are commonly used, with ongoing development of new technologies.
- Comparing the clinical performance of different bioprosthetic valves is essential for surgical decision-making.
Purpose of the Study:
- To compare the early and midterm clinical outcomes of AVR using the INSPIRIS RESILIA bioprosthesis (IR-B) versus the AVALUS bioprosthesis (AV-B).
Main Methods:
- A single-centre retrospective study of 256 patients undergoing AVR between August 2018 and June 2023.
- Patients received either the INSPIRIS RESILIA bioprosthesis (n=156) or the AVALUS bioprosthesis (n=100).
- Propensity score matching was used to compare freedom from death, freedom from major adverse cardiovascular events (MACE), and echocardiographic data.
Main Results:
- After propensity score matching, 1-year survival rates were 93.8% (IR-B) and 94.5% (AV-B), with no significant difference at 3 years (p=0.88).
- Freedom from MACE at 3 years was comparable: 93.2% (IR-B) vs 92.8% (AV-B) (p=0.90).
- Mean aortic pressure gradients and left ventricular mass index changes were similar between the IR-B and AV-B groups over 3 years.
Conclusions:
- Early and midterm clinical outcomes were comparable between the INSPIRIS RESILIA bioprosthesis and the AVALUS bioprosthesis.
- Both bioprosthetic valves demonstrate similar safety and efficacy profiles in patients undergoing aortic valve replacement.
- These findings support the use of both IR-B and AV-B in clinical practice.