Related Experiment Video
Updated: Sep 16, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Effect of cavity depth on degree of conversion and microhardness of low-shrinkage resin composites
Seda Gömleksiz1, Oğuzhan Gömleksiz2
1Department of Restorative Dentistry, Faculty of Dentistry, Erzincan Binali Yıldırım University, Erzincan, Turkey. sedaozkanoglu1@gmail.com.
Background:
The study aimed to investigate the effect of different cavity depths on the degree of conversion (DC) and surface microhardness (MH) of low-shrinkage resin composites.
Methods:
Three low-shrinkage resin composites (Clearfil Majestry Posterior/CMP, Beautifil II LS/BL, Charisma Diamond/CD) and one conventional nanohybrid resin composite (Filtek Z550/FZ) as control were evaluated. For each composite material, a total of 12 disc-shaped samples were prepared using plastic molds with two different depths (2 mm and 4 mm) (n = 6). The same sample preparation protocol was applied for the DC and MH tests, and a total of 96 samples were prepared, 48 for each test. Resin composites filled into molds with the incremental technique were cured with LED light unit only from the top surface. DC was determined by Fourier transform infrared (FTIR) spectroscopy; MH was determined using the Vickers hardness tester. Data were statistically analyzed using Robust and two-way variance analyses (p < 0.05).
Results:
For all resin composites, there was no significantly difference in DC and MH between the 2 mm and 4 mm cavity depths. BL showed the highest DC values at both cavity depths, while CD showed the lowest (p < 0.001). At both cavity depths, the highest MH values on bottom-top surfaces were obtained in CMP, while the lowest were in BL. The top surface MH values were higher in all resin composites than the bottom surfaces.
Conclusions:
Increasing cavity depth may not negatively affect the DC and MH of low-shrinkage resin composites. Moreover, resin composite material formulations may have a higher potential effect on these parameters.
Clinical Trial Number:
Not applicable.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Porosity in Cement Paste
The balance of water to cement in the mix is...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
Curing of Concrete
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...