Related Experiment Video
Updated: Sep 16, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Dosimetric investigation of a rotating gamma ray system
Ahmed A Eldib1, Iavor Veltchev1, Lili Chen1
1Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, United States of America.
None:
Background. Radiosurgery has become an important treatment alternative to surgery for a variety of intracranial lesions. All commercially available systems use convergent beam techniques, but they differ in their treatment delivery methods depending on the machine design and workspace.Purpose. The aim of this work is to investigate a new design for a gamma ray system developed for both intra and extra-cranial stereotactic body radiation therapy (SBRT).Methods. Monte Carlo simulations have been conducted to evaluate rotational radiation delivery using Cobalt-60 gamma beams as compared to linac beams with higher energies. A rotating gamma ray system (RGS), has been modeled using the MCBEAM Monte Carlo code. Treatment plans have been generated utilizing MCPLAN, which is an in-house Monte Carlo treatment planning system. Dosimetric differences between RGS Cobalt-60 beams and Robotic arm linac (RAL) 6 MV beams have been compared in a lung phantom and for previously treated SBRT patients.Results. Results showed that the need for high-energy photon beams decreases with rotational delivery treatments. Cobalt-60 beams could provide a reasonable compromise between beam penetration and penumbra characteristics for lung SBRT applications. The proper combination of available collimator cone sizes and various oblique beam angles allows RGS to shape the isodose lines effectively to match the target volume. The treatment plan quality for RGS has been comparable to that of RAL for both intra- and extra cranial cases. Intensity modulated arcs are feasible with RGS and can add more planning capabilities.Conclusions. The rotating design of the RGS can be of clinical benefit for stereotactic radiation therapy treating cranial cases plus the added ability of treating extra-cranial cases.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Radiation: Applications
The average...
Absorption of Radiation