Related Experiment Video
Updated: Sep 16, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
2-D Stationary Wavelet Transform and 2-D Dual-Tree DWT for MRI Denoising
Mourad Talbi1, Brahim Nasraoui2, Arij Alfaidi2
1Laboratory LMEEVED, Center of Biotechnogy of Borj Cédria, Hammam-Lif, Tunisia.
Introduction:
The noise emergence in the digital image can occur throughout image acquisition, transmission, and processing steps. Consequently, eliminating the noise from the digital image is required before further processing. This study aims to denoise noisy images (including Magnetic Resonance Images (MRIs)) by employing our proposed image denoising approach.
Methods:
This proposed approach is based on the Stationary Wavelet Transform (SWT 2-D) and the 2 - D Dual-Tree Discrete Wavelet Transform (DWT). The first step of this approach consists of applying the 2 - D Dual-Tree DWT to the noisy image to obtain noisy wavelet coefficients. The second step of this approach consists of denoising each of these coefficients by applying an SWT 2-D based denoising technique. The denoised image is finally obtained by applying the inverse of the 2-D Dual-Tree DWT to the denoised coefficients obtained in the second step. The proposed image denoising approach is evaluated by comparing it to four denoising techniques existing in literature. The latters are the image denoising technique based on thresholding in the SWT-2D domain, the image denoising technique based on deep neural network, the image denoising technique based on soft thresholding in the domain of 2-D Dual-Tree DWT, and Non-local Means Filter.
Results:
The proposed denoising approach, and the other four techniques previously mentioned, are applied to a number of noisy grey scale images and noisy Magnetic Resonance Images (MRIs) and the obtained results are in terms of PSNR (Peak Signal to Noise Ratio), SSIM (Structural Similarity), NMSE (Normalized Mean Square Error) and Feature Similarity (FSIM). These results show that the proposed image denoising approach outperforms the other denoising techniques applied for our evaluation.
Discussion:
In comparison with the four denoising techniques applied for our evaluation, the proposed approach permits to obtain highest values of PSNR, SSIM and FSIM and the lowest values of NMSE. Moreover, in cases where the noise level σ = 10 or σ = 20, this approach permits the elimination of the noise from the noisy images and introduces slight distortions on the details of the original images. However, in case where σ = 30 or σ = 40, this approach eliminates a great part of the noise and introduces some distortions on the original images.
Conclusion:
The performance of this approach is proven by comparing it to four image denoising techniques existing in literature. These techniques are the denoising technique based on thresholding in the SWT-2D domain, the image denoising technique based on a deep neural network, the image denoising technique based on soft thresholding in the domain of 2 - D Dual-Tree DWT and the Non-local Means Filter. All these denoising techniques, including our approach, are applied to a number of noisy grey scale images and noisy MRIs, and the obtained results are in terms of PSNR (Peak Signal to Noise Ratio), SSIM(Structural Similarity), NMSE (Normalized Mean Square Error) and FSIM (Feature Similarity). These results show that this proposed approach outperforms the four denoising techniques applied for our evaluation.
Related Concept Videos
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...