A comparative analysis of conduction system pacing and biventricular pacing in patients undergoing atrioventricular
Akash K Mavilakandy1,2, Ahmed M Abdelrazik1,2, Khaled Abouelmagd3
1Department of Cardiology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester LE3 9QP, UK.
Aims:
Atrioventricular node ablation (AVNA) with permanent pacemaker implantation is an established rate-control treatment approach for patients with AF with uncontrolled ventricular rates. Conduction system pacing (CSP) utilizing His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has advanced as a treatment alternative to standard right ventricular pacing in addition to biventricular pacing (BVP). This systematic review and meta-analysis aim to provide a comprehensive summary and evaluation of clinical outcomes in the literature for CSP in comparison to BVP in conjunction with AVNA.
Methods And Results:
This study protocol was registered in the PROSPERO registry (CRD42024510974), and the review was conducted as per the PRISMA guidelines. Databases were searched for relevant studies from inception till 11 January 2024. Results were synthesized using a random effects meta-analysis. From a total of 259 references identified, 122 full texts were assessed, and 25 studies were included in the systematic review. Of these included studies, five were used for comparative meta-analysis. A total of 1652 (HBP 1069 and LBBAP 644) and 369 patients received CSP and BVP implantation with AVNA, respectively. Conduction system pacing resulted in a narrower QRS duration (QRSd) with a change of -35.8 ms (95% CI -61.8 to -9.72; P < 0.05; I2 = 96.3%) vs. BVP. Conduction system pacing also resulted in better symptomatic improvement in from of NYHA reduction (MD -0.53, 95% CI -1.01 to -0.04, I2 = 62.1; P = 0.03). For left ventricular ejection fraction, a non-significant weighted mean increases of 3.36% (95% CI -0.75-7.47%; P = 0.11, I2 = 68.5%) was observed following CSP implantation in comparison to BVP. Conduction system pacing showed no significant differences in procedural and fluoroscopy times and had comparable periprocedural complications. His bundle pacing demonstrated a non-significant reduction in the events of acute threshold elevation in comparison to BVP (Log odds ratio -0.69, 95% CI -2.05-0.66, I2 = 0.00; P = 0.32).
Conclusion:
Conduction system pacing with AVNA is a safe and feasible treatment option for symptomatic (AF) patients undergoing a pace and ablate strategy, offering an alternative to BVP. Overall, CSP results in a narrower QRS duration while providing comparable clinical and echocardiographic outcomes.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Electrophysiology of Normal Cardiac Rhythm
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Dysrhythmias VI: Management of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias