Related Experiment Video
Updated: Sep 16, 2025

Design and Optimization Strategies of a High-Performance Vented Box
Published on: June 9, 2023
Ventilation Design of an Extra-Long Single-Bore Double-Track Railway Tunnel with High Traffic Density
Xiaohan Chen1,2, Sanxiang Sun1, Jianyun Wu1
1School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
Abstract:
Harmful gases produced by diesel locomotives tend to accumulate within tunnels, posing risks such as dizziness, vomiting, coma, and even death to the working staff, particularly in long tunnels with high traffic density. As the number of such structures increases, ventilation in extra-long tunnels represents a critical challenge within the engineering area. In this study, the ventilation of an extra-long single-bore double-track tunnel operating with diesel locomotives is investigated. Through scale model tests and based on the inspection sensor data, the natural diffusion patterns of harmful gases under various operating conditions were elucidated. Based on the local resistance coefficient optimization theory and numerical simulations, the ventilation shafts of the tunnel were optimally designed, and an overall ventilation scheme was developed. The ventilation effect of the tunnel was verified through improved scale model tests. The results show that harmful gases primarily diffuse towards the higher elevation tunnel entrance, with only gases near the lower entrance escaping from it. Under the same operating conditions, NO2 diffuses more slowly than CO, making it harder to discharge. Applying the local resistance coefficient optimization theory, the inclined and vertical shafts of the tunnel can be effectively optimized. The optimized ventilation shafts, coupled with jet fans, can reduce harmful gas concentrations below safety limits within one minute. The methodologies and findings presented here can offer valuable guidance for the ventilation design of similar infrastructures.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Design of Transmission Shafts
Thin-Walled Hollow Shafts
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Design Example: Design of an Irrigation Channel
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:

