Related Experiment Video
Updated: Sep 16, 2025

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Stress Distribution in Interlocking and Blocking Screw Fixation for Distal Tibial Intramedullary Nailing: A Finite
Gu-Hee Jung1,2, Se-Lin Jeong2, Jungtae Ahn1,2
1Department of Orthopaedic Surgery, Gyeongsang National University, College of Medicine, Gyeongsang National University Changwon Hospital, Samjeongja-ro 1, Seongsan-gu, Changwon-si 51472, Republic of Korea.
None:
Background/Objectives: This study evaluates the structural strength of various fixation models for distal tibial fractures using finite element analysis, comparing the biomechanical performance of different interlocking and blocking screw configurations in intramedullary nail fixation. Methods: Finite element models were developed for three different screw configurations: two interlocking screws (T2S), three interlocking screws (T3S), and two interlocking screws combined with two blocking screws (T2SBS2). Material properties were assigned using SAWBONES® models, reflecting established biomechanical characteristics. The models were subjected to static axial loading (800 Nm), internal rotation (3500 Nm), and external rotation stresses. The stress distribution and structural integrity of each fixation model were analyzed. Results: The T3S model demonstrated the lowest maximum von Mises stress values across all loading conditions. Under axial loading, the maximum VMS at the medial first screw contact was the lowest in the T3S model (65.96 MPa) compared to T2S (135.68 MPa) and T2SBS2 (150.30 MPa). Similarly, internal rotation loading resulted in the lowest stress at the medial first screw site in T3S (64.86 MPa), compared to significantly higher stresses in T2S (136.29 MPa) and T2SBS2 (158.11 MPa). The T2SBS2 configuration showed effective stress reduction at the distal interlocking screws, highlighting its potential for improved load sharing. Conclusions: The findings underscore the importance of the secure fixation of the initial interlocking screw in distal tibial fractures. The fixation model utilizing three interlocking screws provided the most favorable overall stress distribution, whereas the inclusion of blocking screws effectively reduced stress concentrations at distal screw sites.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Stress Concentrations in Circular Shafts
Applications of Stress
The...
Design of Transmission Shafts - Stress Analysis
Bearing Stress
Due to the intricacy of these microforces, an average value, known as bearing stress, is often used by...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Stresses under Combined Loadings