Related Experiment Video
Updated: Sep 16, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Innovative Cross-Shaped SRC Column-RC Slab Connection: Experimental Investigation and Finite Element Analysis of
Wei Zhang1, Jianyang Xue2,3, Jinjun Xu4
1School of Energy and Architecture, Xihang University, Xi'an 710077, China.
Abstract:
Flat slab structures are extensively utilized in modern construction owing to their efficient load transfer mechanisms and optimized space utilization. Nevertheless, the persistent issue of brittle punching shear failure at connection zones continues to pose significant engineering challenges. This study proposes an innovative cross-shaped steel-reinforced concrete (SRC) column-slab connection. Through combining test and numerical analyses, the failure mechanisms and performance control principles are systematically analyzed. A refined finite element model incorporating material nonlinearity, geometric characteristics, and interface effects is developed, demonstrating less than 3% error upon test validation. Using the validated model, the influence of key parameters-including concrete strength (C30-C60), reinforcement ratio (ρ = 0.65-1.77%), shear span-depth ratio (λ = 3-6), and limb height-to-thickness ratio (c1/c2 = 2-4)-on the punching shear behavior is thoroughly investigated. The results demonstrate that increasing concrete strength synergistically improves both punching shear capacity (by up to 49%) and ductility (by 33%). A critical reinforcement ratio threshold (0.8-1.2%) is identified. When exceeding this range, the punching shear capacity increases by 12%, but reduces ductility by 34%. Additionally, adjusting the shear span-depth ratio enables controlled failure mode transitions and a 24% reduction in punching shear capacity, as well as a 133% increase in displacement capacity. These results offer theoretical support for the design and promotion of this novel structural system.
Related Concept Videos
Shearing Stresses in a Beam: Problem Solving
Unsymmetric Loading of Thin-Walled Members
The concept of the shear center is crucial in countering the...
Design of Columns under an Eccentric Load
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Shear and Bending Moment Diagram: Problem Solving
Draw a Free-Body Diagram: Start by drawing a free-body diagram of the entire beam, including the concentrated loads, distributed load, and reaction...
Torsion of Noncircular Members