Related Experiment Video
Updated: May 4, 2026

Retroductal Submandibular Gland Instillation and Localized Fractionated Irradiation in a Rat Model of Salivary Hypofunction
Published on: April 24, 2016
Dir-based dose accumulation for parotid glands in head and neck cancer: Accuracy and implications for adaptive
Yong Gan1, Johannes A Langendijk2, Edwin Oldehinkel2
1University of Groningen, University Medical Center Groningen, Department of Radiation Oncology, Groningen, the Netherlands; Shantou University, Cancer Hospital of Shantou University Medical College, Department of Radiotherapy, China.
Background And Purpose:
Deformable image registration (DIR) is widely utilized for dose accumulation, but errors in image registration can compromise its accuracy. This study evaluated the precision of DIR in dose accumulation for parotid gland and proposed a method to correct errors induced by DIR.
Materials And Methods:
This retrospective study included 123 patients with head and neck cancer. For each patient, the accumulated mean dose (Dmean) to the parotid gland was obtained by manual segmentation (ground truth) and two DIR strategies: contour propagation and dose mapping. The normal tissue complication probability (NTCP) model predicting xerostomia was employed to translate accumulated Dmean into NTCP values. Comparisons were made between ground truth and DIR for accumulated Dmean and NTCP.
Results:
The maximum discrepancy of accumulated Dmean and NTCP between DIR and ground truth was 4.87 Gy and 3.94 %, respectively. The discrepancies of accumulated Dmean between DIR and ground truth were significantly correlated with the discrepancies between accumulated Dmean of ground truth and nominal Dmean. Mid-treatment weekly Dmean discrepancies between contour propagation and manual segmentation showed the capability to correct the accumulated Dmean of DIR and decrease the error of NTCP prediction from 2.89 % and 3.81 % to 1.26 % and 2.04 % for baseline xerostomia Grade 0 and Grade 1-2, respectively.
Conclusions:
Significant discrepancies were observed in accumulated Dmean of parotid glands between DIR and manual segmentation in candidates for adaptive radiotherapy. Utilizing mid-treatment CT scans offers a practical solution to correct DIR-induced errors, improving the accuracy of dose accumulation.