One-lung ventilation and right-sided double-lumen tubes: a national survey of current practice in Japan
Taishi Saito1, Kyosuke Takahashi2, Yusuke Iizuka3
1Department of Anesthesiology and Critical Care Medicine, Jichi Medical University Saitama Medical Center, 1-847, Amanuma-Cho, Omiya-Ku, Saitama, 330-8503, Japan. saito.taishi.md@gmail.com.
Background:
One-lung ventilation (OLV) is an essential technique in thoracic surgery, and double-lumen endobronchial tubes (DLTs) are commonly used. While right-sided DLTs are useful in specific situations, few studies have investigated the prevalence of their use. This study aimed to investigate the current practice of OLV and right-sided DLT usage among anesthesiologists in Japan.
Methods:
A nationwide cross-sectional survey was conducted in September 2024, targeting 1444 hospitals certified by the Japanese Society of Anesthesiologists. Questionnaires were mailed to anesthesiology departments, inquiring about OLV practices, right-sided DLT usage, challenges, and desired improvements. Responses were collected via postal mail or web, and data were analyzed using descriptive statistics and Chi-square tests.
Results:
A total of 768 institutions responded (response rate: 53.2%). Among 761 valid responses, 74.9% performed OLV, and DLTs were the most frequently used device (94.7%). Approximately half (45.8%) of the institutions performing OLV reported never using right-sided DLTs. Frequently recognized challenges included insertion difficulty, positioning difficulty, and unfamiliarity, and 42.1% of institutions expressed a willingness to increase the use of right-sided DLTs if these challenges were resolved. Institutions with a higher annual volume of OLV cases tended to use right-sided DLTs more frequently, but the proportion of institutions unfamiliar with right-sided DLTs was not associated with the number of OLV cases performed.
Conclusion:
OLV is widely practiced in Japan, primarily using DLTs, while the use of right-sided DLTs is limited. Concerns over technical difficulties and complications may hinder the use of right-sided DLTs.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: