Quantitative Computed Tomography and Magnetic Resonance Assessment of Vascular Compression in the Thoracic Outlet
Ludo Schropp1, Evert-Jan Vonken2, Maarten L J Smits2
1Department of Vascular Surgery, University Medical Centre Utrecht, Utrecht, the Netherlands.
Objective:
Diagnostic criteria for venous and arterial thoracic outlet syndrome (TOS) are heterogeneous. Detailed guidance on imaging methods and reporting is lacking. This study examined the reliability of a standardised method to quantify vascular compression in the thoracic outlet on dynamic computed tomography (CT) and magnetic resonance (MR) imaging.
Methods:
A standardised and pragmatic method to calculate changes in area using the major and minor diameter of the subclavian artery and vein in the sagittal plane during adduction and abduction was investigated. In a single TOS expertise centre, all CT and MR scans performed according to the TOS protocol were retrospectively identified and independently analysed by four observers using the pre-defined measurement method. Intraclass correlation coefficients were calculated to assess inter- and intra-observer reliability, with thresholds of < 0.5 (poor), 0.5 - 0.75 (moderate), > 0.75 - 0.9 (good), and > 0.9 (excellent).
Results:
Fifty-one CT scans (102 arms) and 58 MR scans (116 arms) were analysed. Venous compression (> 50%) was more prevalent compared with arterial compression both in the CT (51% vs. 16%) and MR (64% vs. 2%) cohorts. Interobserver agreement for CT measurements was 0.79 (95% confidence interval [CI] 0.69 - 0.86) and 0.82 (95% CI 0.75 - 0.88) for arterial and venous compression, respectively; intra-observer agreement was 0.80 (95% CI 0.72 - 0.86) and 0.84 (95% CI 0.76 - 0.89), respectively. For MR measurements, interobserver agreement was 0.36 (95% CI 0.16 - 0.53) and 0.38 (95% CI 0.20 - 0.54) for arterial and venous compression, respectively; intra-observer agreement was 0.39 (95% CI 0.23 - 0.54) and 0.60 (95% CI 0.47 - 0.71), respectively.
Conclusion:
The pre-defined measurement protocol applied to standard CT imaging proved reliable for both arterial and venous quantification of vascular compression. The same measurement protocol applied on MR imaging showed poor inter- and intra-observer reliability. Use of this standardised measurement protocol with CT in prospective multicentre studies on vascular TOS is advocated.
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT