Color K-edge angiography with a dedicated gadolinium-based contrast agent for spectral photon-counting computed
Christian Alejandro Hernandez-Fajardo1, François Lux2, Tristan Doussineau3
1University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, 69621, 69100 Villeurbanne, France.
Purpose:
The purpose of this study was to investigate the feasibility of using a gadolinium (Gd)-based ultrasmall rigid platform (USRP) for angiography imaging using color K-edge imaging with spectral photon-counting CT technology in a rabbit model.
Materials And Methods:
Ten atherosclerotic rabbits with a mean weight of 3.1 ± 0.5 (standard deviation) kg, underwent intravenous administration of an USRP solution (15 mL; 2.5 mL/s; 0.27 mol Gd3+/L). A sub-group of six rabbits also received gadoteric acid (7.8 mL; 1.4 mL/s; 0.5 mol Gd3+/L) for paired comparisons. Rabbits were imaged using a clinical SPCCT prototype (120 kVp; 100 mAs; 0.5-s rotation time; 1.17 pitch). The whole aorta was scanned 6 s post-injection (first pass), followed by abdominal scanning at 30 s, 1-, 3- and 10 min. Two-readers assigned aneurysm grades (expressed as a % vessel dilatation). Median, 25th, and 75th percentiles were used to compare first-pass signals. Mean signal differences in biodistribution for both agents were compared in the aorta, vena cava, and renal pelvis using t-test or Wilcoxon signed-rank test. Signals from both conventional CT and color K-edge images were analyzed.
Results:
Mean aneurysm grades for both image types were 45 %. A matching first-pass signal was achieved for both agents (P = 0.98), with median concentrations of 7.8 mg/mL (6.9, 8.4) vs. 7.6 mg/mL (6.4, 8.6) for USRP and gadoteric acid, respectively. Following timepoints showed similar blood pool signal among agents, but a minimal increase in average signal (mean signal difference = 17 Hounsfield unit or 0.2 mg/mL; P < 0.05) for both vessels in favor of USRP. High Gd concentrations in the renal pelvis for both agents indicated similar renal excretion profiles (mean signal difference of 0.9 mg/mL; P > 0.05).
Conclusion:
Gd-based USRPs can be used for color K-edge angiography imaging, representing viable contrast media candidates for emerging spectral photon-counting CT applications.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography