Related Experiment Video
Updated: Sep 15, 2025

Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Drone- and Paper-Based Analytical Devices: A Powerful Combination for the Colorimetric Detection of Tropospheric
Pedro P E Campos1, Habdias A Silva-Neto1,2, Lucas C Duarte1
1Instituto de Química, Universidade Federal de Goia's, Goiânia, Goiás 74690-900, Brazil.
None:
Ozone is a harmful atmospheric pollutant whose elevated concentrations (i.e., higher than 0.16 mg m-3) and prolonged exposure cause severe damage to the human respiratory system and negatively affect flora and fauna. Vertical ozone monitoring remains challenging due to the limitations of traditional sensors, which are bulky, expensive, and slow to provide results at the site of interest. To address this problem, there is a critical need for portable technologies that allow for rapid and efficient in situ detection. This study presents, for the first time, the integration of paper-based analytical devices (PADs) with a commercial drone to combine them for remote sampling and ozone colorimetric detection. The PADs were manufactured using a stencil-printing technique on chromatographic paper, with circular vinyl stencil masks (Ø = 5 mm) applied to define the detection areas on the paper. The hydrophobic barrier was created by depositing varnish resin onto the stencil/paper surface, with the masks removed after drying, resulting in PADs ready for use. As proof of concept, the paper detection zone surfaces were impregnated with potassium indigotrisulfonate (ITS) and polyethylene glycol (PEG), aiming to sample and detect gaseous ozone. The colorimetric method was performed using a desktop scanner to capture images, which were analyzed by graphical software to evaluate the resulting color intensity that varied from blue to colorless. A commercial ozone generator was used to optimize the method parameters. Parameters such as reaction time, reagent volume, and PEG concentration were optimized, resulting in a linear response range for ozone between 0.9 and 7.6 mg, with an R2 of 0.996, and a limit of detection of approximately 0.25 mg. A customized holder was fabricated by 3D printing to ensure the attachment of PADs on the aerial drone platform. The system successfully monitored tropospheric ozone levels, recording 6.8 ± 0.7 mg during the dry season and 0.9 ± 0.1 mg during wet periods, with an in-flight sampling time of just 120 s. This innovative system has great potential to advance environmental monitoring, offering a portable, low-cost solution for remote and real-time ozone detection.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Atomic Emission Spectroscopy: Instrumentation

