Evaluation of THOR-50M-RS under reclined seating conditions
Kathleen D Klinich1, Nichole R Orton1, Carl Miller1
1Transportation Research Institute, University of Michigan, Ann Arbor, Michigan.
Objective:
Testing was conducted to evaluate the performance of the THOR-50M for Reclined Seating (THOR-50M-RS) with modifications to allow for a more realistic posture and impact response under reclined seating conditions. Results were compared to tests conducted with PMHS under the same conditions.
Methods:
Nine frontal sled tests were conducted using the THOR-50M-RS in a controlled response seat with the seatback angle set to 45 degrees. Three tests were conducted under each of three conditions: (1) nominal 32 km/h delta V, 4.5 kN seatbelt load limiter (LL), knee bolster condition 1 (180 mm spacing); (2) nominal 50 km/h delta V, 2.7 kN LL, knee bolster condition 1; and (3) nominal 50 km/h delta V, 2.7 kN LL, knee bolster condition 2 (100 mm spacing). The ATD was positioned using a seating procedure based on data from volunteers in reclined seats. THOR-50M-RS instrumentation prioritized channels that could be directly compared to PMHS tests, such as head, T1, and pelvis accelerations. Ten cameras were used to track matching kinematic targets for comparison. Emphasis was placed on qualitative comparison of the head, spine, hip, and knee kinematics, but differences were also quantified using Correlation and Analysis (CORA) techniques. Injury assessment reference values (IARVs) were also calculated.
Results:
The ATD showed good repeatability within test conditions. Minor durability issues included pelvis flesh damage that was repaired and did not reoccur, as well as upper thigh flesh fraying at the rear seams. Comparison to kinematics from PMHS tests run in the same conditions indicated that the response of the THOR-50M-RS generally aligned well with the PMHS signals. However, the initial narrow width of PMHS corridors often led to low CORA scores, with a range of 0.03 to 0.98 across all test conditions and signals.
Conclusions:
The THOR-50M-RS was able to meet target postures in reclined seats and showed good repeatability within a given test condition. These tests demonstrate the challenges of designing effective occupant protection systems for occupants in reclined postures, with chest and lumbar spine injury measures exceeding recommended limits (derived for non-reclined modes) in the higher-speed (50 km/h) testing condition.
More Related Videos
08:40Quantifying Arms and Legs Contributions during Repetitive Electrically-Assisted Sit-To-Stand Exercise in Paraplegics: A Pilot Study
Published on: November 11, 2022
06:11Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Normal and Tangetial Components: Problem Solving