Related Experiment Video
Updated: Jul 14, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Beyond the Image: Performance of O-RADS, ADNEX, IOTA Simple Rules & RMI 4 in differentiating benign and malignant
Gaurav Khastgir1, Sujata Siwatch1, Tulika Singh2
1Department of Obstetrics & Gynaecology, Post Graduate Institute of Medical Education & Research (PGIMER), Chandigarh, India.
Aim:
To prospectively and externally validate O-RADS (Ovarian-Adnexal Reporting and Data System), RMI 4 (Risk of Malignancy Index), IOTA SR (International Ovarian Tumour Analysis Group Simple Rules) and ADNEX Rules (Assessment of Different NEoplasias in the adneXa), and compare their diagnostic accuracy in differentiating benign and malignant Adnexal Masses (AM) in the Indian population.
Study Design:
This single-centre diagnostic accuracy study included 100 consecutive consenting women with AM presenting to the gynaecology department at a tertiary care centre in Northern India. Every AM was classified as benign or malignant using O-RADS, RMI4, IOTA SR, and the ADNEX model (with CA 125). The reference standard was histopathological diagnosis. Sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios and overall accuracy were determined for all systems among various age groups and histopathological subtypes.
Results:
Of the 100 women (mean age 42 ± 16.8 years) recruited, 45 had histopathologically benign lesions, 41 malignant and 14 borderline AM. O-RADS showed the highest sensitivity at 98 % (95 % CI: 87.4-99.5), followed by IOTA SR at 95 % (95 % CI: 83.8-98.6), RMI 4 at 88 % (95 % CI: 74.4-94.6), and ADNEX at 87.8 % (95 % CI: 73.8 %-95.9 %). However, ADNEX demonstrated the maximum specificity at 93 % (95 % CI: 81.7 %-98.6 %), followed by RMI 4 at 89 % (95 % CI: 76.5-95.1), IOTA SR at 87 % (95 % CI: 73.82-93.74), and O-RADS at 53 % (95 % CI: 39.1-67.1). Overall, ADNEX and IOTA SR showed the highest and similar diagnostic accuracy at 91 % (95 % CI: 82.7-95.2), followed by RMI 4 at 88 % (95 % CI: 79.9-93.5) and O-RADS at 74 % (95 % CI: 64.2-82.4).
Conclusion:
The O-RADS, IOTA Simple Rules and ADNEX performed well in distinguishing benign from malignant adnexal masses in an Indian population among various age groups and histopathological subtypes. While O-RADS was the most sensitive, the ADNEX model showed the best specificity. Additionally, RMI 4 is a robust diagnostic tool with strong diagnostic accuracy, outlining the importance of its application in low-resource settings.
More Related Videos
07:54Surface-enhanced Resonance Raman Scattering Nanoprobe Ratiometry for Detecting Microscopic Ovarian Cancer via Folate Receptor Targeting
Published on: March 25, 2019
10:21A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023