Comparing respiratory variables with circle, Bain and T-piece breathing systems in 5-10 kg dogs: a randomized
Andrew G Murray1, Kerry Woodhouse1, Pamela J Murison1
1University of Glasgow Small Animal Hospital, 464 Bearsden Road, Glasgow, G61 1QH, UK.
Objective:
To compare respiratory rate (fR), end-expired carbon dioxide (Pe'CO2) and tidal (Vt) and minute (V˙ E) volume through a Bain or circle breathing system against a T-piece control.
Study Design:
Randomized, non-blinded, crossover clinical trial.
Animals:
A group of 30 client-owned dogs (5-10 kg) undergoing general anaesthesia for elective procedures.
Methods:
Equal groups of dogs were randomly allocated to the test breathing systems (either circle or Bain) then the order of breathing systems was randomized (test or control first). All dogs received a standard anaesthetic protocol. Following induction, 10 minutes was allowed to achieve a stable anaesthetic plane. Measurements were obtained over a 5 minute window for each system. After each breathing system change, 5 minutes was allowed for the dog to adjust. Measurements were compared using a paired Student's t-test or Wilcoxon rank test.
Results:
The circle Pe'CO2 (6.04 ± 0.64 kPa), Vt (12.1 ± 3.9 mL kg-1) and V˙e [116.7 (97.5-166.0) mL kg-1 minute-1] were significantly higher (p = ≤ 0.001, 0.035 and 0.002, respectively) than the T-piece Pe'CO2 (5.31 ± 0.78 kPa), Vt [10.6 (7.7-13.3) mL kg-1] and V˙ E [107.8 (77.3-131.9) mL kg-1 minute-1]. The Bain Pe'CO2 (5.22 ± 0.98 kPa) was significantly lower (p = 0.032) and the Vt (7.1 ± 2.7 mL kg-1) significantly higher (p = 0.041) than the T-piece Pe'CO2 (5.61 ± 0.90 kPa) and Vt [6.6 (4.8-7.0) mL kg-1]. Between the Bain and T-piece there was no significant difference in V˙ E. fR was similar in both systems compared with the control.
Conclusions And Clinical Relevance:
While differences were found between both test systems and the control, the clinical consequences appear minimal. Both circle and Bain, appear suitable for use in healthy 5-10 kg dogs as overall ventilatory function was adequate.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities I
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...