Related Experiment Video
Updated: Sep 14, 2025

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Highly sensitive hydrogen analysis employing low pressure laser induced breakdown spectroscopy in helium surrounding
Indra Karnadi1, Marincan Pardede2, Rinda Hedwig3
1Department of Electrical Engineering, Krida Wacana Christian University, Jakarta, 11470, Indonesia.
Abstract:
We conduct an experimental study to search for the urgently needed method for routine, no sample pretreatment, in-situ, and less-destructive analysis of Hydrogen (H) content in Zircaloy-4 tube used as radioactive fuel container in light water nuclear power plant. For this purpose, we implemented laser-induced breakdown spectroscopy (LIBS) in Helium (He) surrounding gas at a relatively low pressure of around 3 kPa and low laser energy of 17 mJ. In addition, we designed a new compact and portable sample chamber accommodating an open end so the chamber can tightly fit the Zircaloy-4 tube surface. Inside the chamber we put electrodes to apply an additional electric field. We found that applying an electric field in the plasma expansion region increases the H emission intensity by a factor of 6. Consequently, the H I 656.2 nm emission line obtained from the Zircaloy-4 sample containing H of 11 ppm impurity featuring a sharp linewidth (0.1 nm) with high signal-to-noise ratio (S/N = 120). Thus, it offers potential applications to non-destructive H analysis in Zircaloy-4 tubes used in light water nuclear power plant. The detection limit of H was estimated less than 0.26 ppm, well below the sensitivity limit of around 600 ppm required for the regular inspection of Zircaloy-4 tubes in light water nuclear power plant.
More Related Videos
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Emission Spectra
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...

