Related Experiment Video
Updated: Sep 14, 2025

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Does the amount of noise generated differ between manual and robotic TJA?
John D D Higgins1, Nabil Mehta2, Vasili Karas1
1Department of Orthopedic Surgery Rush University Medical Center, 1611 W Harrison St., Chicago, IL 60612, USA.
Noise exposure during total joint arthroplasty (TJA) is significant, but neither manual nor robotic techniques exceeded Occupational Safety Health Administration (OSHA) limits for peak sound pressure or 8-hour time-weighted averages.
Area of Science:
- Orthopedic Surgery
- Surgical Technology
- Occupational Health
Background:
- Surgical noise levels during total joint arthroplasty (TJA) are not well-characterized.
- Understanding noise exposure is crucial for surgeon and staff safety.
Purpose of the Study:
- To compare noise levels generated during manual versus robotic-assisted TJA.
- To determine if surgical noise exceeds Occupational Safety Health Administration (OSHA) action limits.
Main Methods:
- Decibel (dB) levels were recorded using personal dosimeters worn by the primary surgeon.
- Both manual and robotic-assisted total hip arthroplasty (THA) and total knee arthroplasty (TKA) procedures were monitored.
- Continuous (LAeq) and peak (LCPeak) decibel levels were captured, and 8-hour Time-Weighted-Average (TWA) was calculated.
Main Results:
- Noise levels were significant in all TJA procedures, with mean LAeq ranging from 69.7 to 71.4 dB.
- Peak sound pressure levels did not exceed OSHA limits in any group.
- Manual THA showed higher average LCPeak values than robotic THA (P=0.01), while TKA showed no significant difference.
Conclusions:
- TJA surgeons experience substantial noise exposure irrespective of surgical technique.
- Neither manual nor robotic techniques resulted in noise levels exceeding established OSHA safety thresholds for peak and TWA exposure.
Related Concept Videos
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...
Mechanical Systems
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
Torque Free Motion
Random and Systematic Errors