First-trimester prediction of early-onset preeclampsia using PAPP-A and mean arterial pressure

Fatma Beyazıt1, Eren Pek1, Murat Daş2

  • 1Çanakkale Onsekiz Mart University, Medical School, Department of Obstetrics and Gynecology, Çanakkale, Turkey.

PubMed

Predicting early-onset preeclampsia (EOP) during the initial stages of pregnancy is essential for effective clinical management and enhancing maternal-fetal outcomes. Current methodologies, which include clinical and demographic risk factors, biophysical parameters, and serum biomarkers, exhibit limited efficacy in predicting EOP. This study aimed to evaluate whether the incorporation of pregnancy-associated plasma protein-A (PAPP-A) and mean arterial pressure (MAP) significantly enhances EOP detection. We conducted a retrospective case-control study involving 518 gravidas, of whom 202 developed EOP and 316 experienced normal pregnancies. Logistic regression models were employed to assess EOP predictions, and the predictive accuracy of these statistical models was evaluated using receiver-operating characteristic curve analysis. Our findings indicate that lower PAPP-A levels, higher MAP, and increased body mass index (BMI) are associated with EOP. Notably, in pregnant women between 11+0 and 13+6 weeks of gestation, a 1-point decrease in PAPP-A corresponds to an 84% increase in the likelihood of developing EOP. The predictive performance of PAPP-A improves significantly when combined with other factors such as BMI, MAP, and a history of diabetes mellitus (DM). The risk of EOP is substantially heightened (20.410 times, 95% CI: 11.104-37.515) in patients exhibiting low PAPP-A levels (<0.88) and high BMI (≥35 kg/m²). Additionally, low PAPP-A combined with elevated MAP levels significantly increases EOP risk (adjusted odds ratio [OR]: 114.83). However, after adjustment, the association between low PAPP-A and a history of DM was not statistically significant (adjusted OR: 2.30, p = 0.202). In conclusion, employing a combination of multiple variables for predicting EOP yields a significant improvement over traditional methods that rely solely on individual factors.

Related Concept Videos

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
35
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
628
Blood Pressure01:24

Blood Pressure

The movement of blood in a human body, commonly referred to as blood flow, is determined by the volume of blood that traverses a certain section of the bodily system per unit time. It is the rhythmic contraction of the heart's ventricles that primarily instigates this movement. As the ventricles contract, blood is forced into the prominent arteries, which then flow from areas of greater pressure to lower pressure areas. This movement continues into smaller arteries and arterioles and...
4.7K
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.5K