High-Throughput Analysis of Optical Mapping Data Using ElectroMap
Published on: June 4, 2019
Automatic measurement of short-term variability of repolarization captures modulation by pacing on human electrograms
Cheyenne S L Chiu1, Vera Loen2, Alfonso Aranda Hernandez3
1Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Background:
Short-term variability of repolarization (STV) increases prior to ventricular arrhythmias in both humans and animal models, making it a promising tool for real-time arrhythmic risk monitoring.
Objective:
An automatic STV measurement algorithm was developed for intracardiac electrograms (EGMs) to enable integration into cardiac devices. This method previously demonstrated high accuracy in predicting life-threatening ventricular arrhythmias in animals. This study compared the performance of the automatic method to the gold standard on EGMs in humans.
Methods:
EGM signals were recorded in 14 patients with a dual-chamber implantable cardioverter-defibrillator during de novo implantation (n = 5) or replacement (n = 9) procedures. Recordings were obtained in sinus rhythm (SR), atrial pacing at 80 beats/min, and dual-chamber pacing at 80 beats/min. STV was determined on the EGM from the activation recovery interval with the automatic method (STV-ARIauto) and with fiducial segment averaging (STV-ARIFSA), the gold standard. STV-ARIauto was compared with STV-ARIFSA for all pacing modes.
Results:
STV-ARIauto and STV-ARIFSA decreased from 0.90 ± 0.51 ms and 0.99 ± 0.39 ms in SR (53 ± 9 beats/min) to 0.60 ± 0.37 ms (and 0.68 ± 0.39 ms in atrial pacing at 80 beats/min, and to 0.32 ± 0.15 ms and 0.59 ± 0.24 ms in dual-chamber pacing at 80 beats/min, respectively (all P < .05 compared with SR). STV-ARIauto strongly correlated with STV-ARIFSA (r = 0.80, P < .0001), with a small bias of 0.18 ms and limits of agreement between -0.35 and 0.70 ms.
Conclusion:
The novel automatic STV measurement method accurately reflects pacing-induced changes, comparable to the gold standard. Future integration of this technique in implantable cardioverter-defibrillators could furnish continuous monitoring of arrhythmic risk and initiate preventive strategies.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrophysiology of Normal Cardiac Rhythm
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....