Related Experiment Video
Updated: Sep 13, 2025

Author Spotlight: A Simple and Cost-Effective Method for Leukocyte Analysis in Semen
Published on: January 19, 2024
Canine Sperm Concentration: Comparison Between Neubauer Cell Counting, Photometers and a CASA System
Rédha Belala1,2, Seddik Kebbal1,2, Myra Medjkoune1,2
1Biotechnologies Laboratory Related to Animal Reproduction (LBRA), Institute of Veterinary Medicine, Saad Dahleb Blida University 1, Blida, Algeria.
None:
This study aimed to compare three methods used in evaluating canine sperm concentration in translucent and opaque media. These techniques were counting chamber; spectrophotometry using two commercial photometers calibrated for canine semen (Accuread and SDM1); and CASA analyzer (Hamilton Thorne IVOS II [HT-IVOS II]), for motile and non-motile spermatozoa (spz). Eight ejaculates were collected, then the sperm-rich fraction of each sample was divided into two aliquots: one was mixed with a translucent commercial buffered solution (Easy Buffer-B) and the other with an opaque egg yolk-based diluent. Each of the two aliquots was separated into five fractions evaluated respectively by the different tools. The results showed that the HT-IVOS II analyzer with immobilised spermatozoa was in good agreement with the reference method (counting chamber), whereas the Accuread photometer showed a reasonable difference, but with poor statistical agreement, while the SDM1 photometer and HT-IVOS II analyzer (with immobilised spz) were in bad agreement with the reference method in assessing translucent media-diluted canine sperm concentration. In the context of semen diluted in an opaque egg yolk-based medium, none of the studied techniques was in agreement with the reference method. The comparison between translucent media-diluted and opaque media-diluted semen revealed that except for the reference method, all evaluation techniques (SDM1, Accuread and HT-IVOS II analyzer) were unreliable (p > 0.05) in assessing sperm concentration across both situations. The authors propose to conduct further studies with an expanded sample size and to incorporate flow cytometry (FCM) into the comparative evaluation techniques.
More Related Videos
08:58Fluorimetric Techniques for the Assessment of Sperm Membranes
Published on: November 28, 2018
19:26Measuring Intracellular Ca2+ Changes in Human Sperm using Four Techniques: Conventional Fluorometry, Stopped Flow Fluorometry, Flow Cytometry and Single Cell Imaging
Published on: May 24, 2013