Related Experiment Video
Updated: Sep 13, 2025

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Comparison of 2 electronic health record data extraction methods for laboratory tests used in the Veterans Aging
Christine Ramsey-Hardy1,2,3, Melissa Skanderson2, Janet P Tate2,3
1Department of Nutritional Sciences, University of Texas at Austin, Austin, TX 78712, United States.
Objective:
To compare Observational Medical Outcomes Partnership (OMOP) Logical Observation Identifiers Names and Codes (LOINC) and Veterans Aging Cohort Study (VACS) methods for extracting laboratory chemistry data from Veterans Health Administration (VA) electronic health records (EHR).
Materials And Methods:
Laboratory chemistry test results for 16 laboratory tests commonly assess in Veterans in VACS HIV (N = 143 830) followed in the VA 2015-2019 were extracted from the EHR and compared using 2 different data extraction approaches.
Results:
The LOINC approach captured laboratory results from all 130 VA stations for all 16 labs. The VACS approach captured laboratory results from 128 to130 stations. Both approaches yielded laboratory results for a patient on a given date for 97% or more of the observations for 10 of the tests, 94%-97% for 5 of the tests, and 89% for 1 test. The percentage of exact matches on the value of the test result exceeded 99% for 10 of the laboratory tests and 92% for all other laboratory tests.
Discussion:
Both approaches resulted in extraction of similar amounts of data in terms of individual patients, VA stations and total observations for all 16 tests. Both approaches yielded high agreement on test results in terms of identical values and correlation of test results for all tests.
Conclusion:
The high level of agreement between VACS and LOINC approaches in this study demonstrate the favorable use of the LOINC approach for extracting laboratory results for most tests due to the ease and efficiency of this approach without compromising validity.
More Related Videos
06:55Inverse Probability of Treatment Weighting Propensity Score using the Military Health System Data Repository and National Death Index
Published on: January 8, 2020
05:35Author Spotlight: Developing a Point-of-Care Hemoglobin Estimation Method for Anemia Management
Published on: January 19, 2024
Related Concept Videos
Methods of Documentation VII: EMR
Data Collection III
The principles to begin the physical assessment include conducting a comprehensive or problem-related history in a quiet, well-lit room, emphasizing privacy and comfort for the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...