Intrathecal Gadolinium-Enhanced MR Cisternography Improves the Detection of Skull Base CSF Leaks
Douglas J Totten1, Nicholas A Koontz, Hunter L Elms1
1Department of Otolaryngology-Head and Neck Surgery, Indiana University, Indianapolis, Indiana.
Objective:
To compare the efficacy of contrast enhanced magnetic resonance cisternography (CE-MRC), computed tomography cisternography (CTC), and single-photon emission computed tomography (SPECT-CT) radionuclide cisternography (RNC) in detection of skull base cerebrospinal fluid (CSF) leaks.
Study Design:
Retrospective cohort study.
Setting:
Tertiary referral center.
Patients:
Adult patients with suspected anterior skull base (ASB) or lateral skull base (LSB) CSF leak who underwent CE-MRC, CTC, and/or SPECT-CT RNC to assess for CSF leak from 2018 to 2024.
Main Outcome Measures:
Evidence of CSF leak on single or multiple cisternogram types.
Results:
Fifty patients (74% female) had a mean (standard deviation) age of 50 (17) years and a median BMI of 34 (IQR, 28-42) kg/m 2 . Nineteen patients had a surgically or laboratory-confirmed CSF leak. Of these, 78% were spontaneous CSF leaks. There were no false-positive tests for any mode of cisternograms. CT cisternograms had a sensitivity of 53% (ASB: 86%, LSB: 33%) compared with a sensitivity of 90% (ASB: 100%, LSB: 86%) for CE-MR cisternograms and 67% (ASB: 100%, LSB: 33%) for SPECT-CT RN cisternograms.
Conclusions:
CE-MRC appears to be more sensitive than CTC and SPECT-CT RNC in detecting skull base CSF leaks, particularly in the lateral skull base. CE-MRC should be used when appropriate in combination with high-resolution CT to assess for CSF leaks when there is a high index of suspicion with inconclusive beta-2 transferrin testing.
Level Of Evidence:
4.
More Related Videos
06:22In Vivo Imaging of Cerebrospinal Fluid Transport through the Intact Mouse Skull using Fluorescence Macroscopy
Published on: July 29, 2019
06:59Intrathecal Application of a Fluorescent Dye for the Identification of Cerebrospinal Fluid Leaks in Cochlear Malformation
Published on: February 29, 2020
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...