Related Experiment Video
Updated: Sep 13, 2025

06:09
Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
3.3K
A comparative analysis of manual glenoid version measurement using two- and three-dimensional computed tomography
Maxwell S Renna1, Ashley I Simpson2
1Trauma and Orthopaedics, Guy's and St Thomas' Hospital, London, United Kingdom.
Clinics in Shoulder and Elbow
|July 31, 2025
Summary
Formatted 2D CT scans offer a reliable alternative for measuring glenoid version when 3D CT is unavailable. This method demonstrates superior accuracy and reliability compared to unformatted 2D CT in shoulder arthroplasty assessments.
Area of Science:
- Orthopedic surgery
- Radiology
- Medical imaging
Background:
- Accurate glenoid version measurement is crucial for successful shoulder arthroplasty.
- Glenoid version influences implant positioning and patient outcomes.
- Current imaging techniques for glenoid version assessment vary in accuracy and reliability.
Purpose of the Study:
- To compare the accuracy and reliability of unformatted 2D CT, formatted 2D CT, and 3D CT reconstructions for glenoid version measurement.
- To determine the best imaging method for reproducible glenoid version assessment in shoulder arthroplasty.
- To evaluate the clinical utility of formatted 2D CT as an alternative to 3D CT.
Main Methods:
- Retrospective analysis of shoulder CT scans from 65 patients undergoing arthroplasty.
- Glenoid version measured using unformatted 2D CT, formatted 2D CT, and 3D CT (Corrected Friedman Method) as the reference standard.
- Inter- and intra-observer reliability and minimally detectable difference were calculated for each method.
Main Results:
- No significant difference in mean glenoid version values across the three methods (P=0.245).
- Formatted 2D CT showed significantly higher agreement with 3D CT (95.4%) compared to unformatted 2D CT (83.1%) (P=0.023).
- 3D CT demonstrated the highest inter- and intra-observer reliability (ICC=0.83 and 0.91, respectively), followed by formatted 2D CT (ICC=0.83 and 0.83).
Conclusions:
- Three-dimensional CT (3D-CT) reconstructions are the gold standard for accurate and reproducible glenoid version assessment.
- Formatted 2D CT serves as a reliable alternative to 3D CT when 3D imaging is not feasible.
- Formatted 2D CT significantly outperforms unformatted 2D CT in accuracy and reliability for glenoid version measurement.
Related Concept Videos
Computed Tomography
6.3K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
6.3K
Imaging Studies III: Computed Tomography
52
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
52

