Related Experiment Video
Updated: Sep 13, 2025

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Methodological approach for a simultaneous determination of persistent and non-persistent organic pollutants in human
Carolina M Bustamante1, Paula Ruiz2, Atiya B Rifat3
1Institute of Environmental Assessment and Water Research (IDAEA-CSIC). Barcelona, Catalonia, Spain; Faculty of Chemistry. Universitat de Barcelona (UB). Barcelona, Catalonia, Spain.
Abstract:
Human biomonitoring of persistent organic pollutants (POPs) remains essential for tracking long-term exposure, evaluating health risks, and assessing the effectiveness of regulatory bans. For this purpose, an experimental and analytical methodology has been optimized allowing the determination of 47 POPs, encompassing chlorinated cyclodienes, chlorobenzenes, cyclohexanes, polychlorodiphenyl derivatives, several congeners of polychlorobiphenyls (PCBs) and polybromodiphenyl ethers (PBDEs, including the deca-BDE), as well as three non-persistent chemicals (namely quintozene, tecnazene and vinclozolin). The method uses a single liquid-liquid extraction procedure with 500 µL of serum/plasma. Instrumental analysis involves gas chromatography (GC) with electron capture detection (ECD) for the analysis of organochlorines, and a subsequent injection into a GC coupled to mass spectrometry in negative chemical ionization mode (MS-NCI) for the determination of PBDEs. The analytical procedure has been successfully validated, demonstrating high sensitivity (limits of detection: 0.0016-0.012 ng/mL; limits of quantification: 0.0029-0.021 ng/mL), acceptable linearity (R² > 0.9962), good precision (coefficients of variation <25%, except for BDE-209), satisfactory accuracy (recoveries within 70-130% for 41 out of 47 compounds) and minimal matrix effects. Proficiency Testing Materials from the AMAP Ring Test for POPs in human serum confirmed the method's reliability with results within the accepted reference range. This method represents an efficient and practical approach for human biomonitoring studies, with a simplified workflow suitable for routine application.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...