Related Experiment Video
Updated: Jun 27, 2026

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
Published on: October 15, 2018
From Solution to Gas Phase: Revealing Ligand-Dependent Conformations of Ribonuclease A with Tandem-Trapped Ion
Fanny C Liu1, Mengqi Chai1, Tianming Qu1
1Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32304, United States.
Abstract:
Protein activity depends on motional transitions between conformational states. Modifications or ligand binding can alter the protein dynamics, leading to changes in activity. Established biophysical methods effectively determine protein structures but face challenges when investigating dynamic biological processes that involve steady states of transiently populated conformations. Ion mobility/mass spectrometry shows promise for studying transient protein conformations but characterizes them in a solvent-free environment and does not directly provide detailed structural information. Here, we investigate to what extent subtly different conformational states are retained in their solvent-free environment. We investigate the conformations of unliganded ribonuclease A (RNase A) and RNase A bound to uracil-3'-monophosphate (3'-UMP) and adenosine-5'-monophosphate (5'-AMP) using our tandem-trapped ion mobility spectrometer/tandem mass spectrometer (Tandem-TIMS) in conjunction with molecular dynamics-based computational approaches. RNase A transitions between a closed and an open conformation on the millisecond time scale, with the closed conformation being favored when liganded. A comparison of our experimental and computational results indicates that both ligand-bound and unliganded RNase A maintain approximately 80% of their native contacts in a solvent-free environment. This includes interactions between the ligand and the protein, as well as the ligand's position within the binding pocket. Furthermore, our experimental data reveal that when solvent-free RNase A is ligand-bound, it maintains a more compact structure, as observed in solution. Additionally, differences between the open and closed conformationssuch as the positioning of Loop 1are mostly preserved in the solvent-free state per our computational analysis, with root-mean-square deviations of about 2 Å. In summary, our findings demonstrate the ability of Tandem-TIMS to characterize subtle structural differences between steady-state protein conformations. This takes on increased significance due to the involvement of transient protein assemblies in cellular signaling and neurodegenerative diseases as well as "hidden" protein states underlying enzyme function that are not directly accessible using established methods.
More Related Videos
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
08:40Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Related Concept Videos
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Atomic Fluorescence Spectroscopy