Related Experiment Video
Updated: Sep 13, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Temporal Profiling of Cytokines in Passively Expressed Sweat for Detection of Infection Using the AWARE Device
Preeti Singh1, Akash Kumar1, Kundan Kumar Mishra1
1Department of Bioengineering, University of Texas at Dallas, Richardson, Texas 75080, United States.
None:
This study highlights the assay development of a wearable AWARE-SENSOR (a wearable awareness with real-time exposure) designed for the noninvasive detection of key pro-inflammatory cytokines, TNF-α and IL-6, in passively perspired sweat. These cytokines are pivotal biomarkers for assessing immune responses, inflammation, and physiological stress. A critical innovation in this platform is the use of aptamers, which offer significant advantages over traditional antibodies in biosensor applications. Aptamers, being synthetic oligonucleotides, are highly specific to their target molecules, providing robust and reproducible binding. Unlike antibodies, aptamers exhibit superior stability under varying environmental conditions, such as temperature, making them ideal for real-time and human body deployable applications, such as wearable sensors. The use of aptamers ensures that the AWARE-SENSOR achieves precise and continuous monitoring capabilities, translating cytokine binding into measurable electrical signals. These features make the device particularly suitable for tracking dynamic changes in inflammatory biomarkers. Herein, we report benchtop validation of a new aptamer sensor for the detection of TNF-α and IL-6 in PBS. The dynamic ranges of TNF-α and IL-6 were 0.1-200 and 1-256 pg/mL, respectively, with sensitivities of 2.77 pg/mL (TNF-α) and 3.22 pg/mL (IL-6) with linear responses R2 = 0.98 (TNF-α) and R2 = 0.97 (IL-6). Interference studies confirmed that the sensor exhibited no significant interference from biomarkers like IL-6, IL-8, and CRP for the TNF-α sensor and vice versa. The AWARE-SENSOR response was also evaluated to detect the biomarkers in human sweat samples with high accuracy within ∼3 min of incubation. The sensing mechanism of the AWARE-SENSOR suggested that the binding of the biomarker to the aptamer on the electrode surface alters the electrical properties of the interface, typically by creating a more conductive pathway due to conformational changes in the aptamer, effectively allowing more electrons to transfer between the electrode and the solution, leading to a lower impedance reading.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...

