Related Experiment Video
Updated: Sep 12, 2025

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Multi-institutional study for comparison of detectability of hypovascular liver metastases between 70- and 40-keV
Shintaro Ichikawa1, Satoshi Funayama1, Tomoko Hyodo2
1Hamamatsu University School of Medicine, Hamamatsu, Japan.
Purpose:
To compare the lesion detectability of hypovascular liver metastases between 70-keV and 40-keV images from dual energy-computed tomography (CT) reconstructed with deep-learning image reconstruction (DLIR).
Methods:
This multi-institutional, retrospective study included adult patients both pre- and post-treatment for gastrointestinal adenocarcinoma. All patients underwent contrast-enhanced CT with reconstruction at 40-keV and 70-keV. Liver metastases were confirmed using gadoxetic acid-enhanced magnetic resonance imaging. Four radiologists independently assessed lesion conspicuity (per-patient and per-lesion) using a 5-point scale. A radiologic technologist measured image noise, tumor-to-liver contrast, and contrast-to-noise ratio (CNR). Quantitative and qualitative results were compared between 70-keV and 40-keV images.
Results:
The study included 138 patients (mean age, 69 ± 12 years; 80 men) with 208 liver metastases. Seventy-one patients had liver metastases, while 67 did not. Primary cancer sites included 68 cases of pancreas, 50 colorectal, 12 stomach, and 8 gallbladder/bile duct. No significant difference in per-patient lesion detectability was found between 70-keV images (sensitivity, 71.8-90.1%; specificity, 61.2-85.1%; accuracy, 73.9-79.7%) and 40-keV images (sensitivity, 76.1-90.1%; specificity, 53.7-82.1%; accuracy, 71.7-79.0%) (p = 0.18-> 0.99). Similarly, no significant difference in per-lesion lesion detectability was observed between 70-keV (sensitivity, 67.3-82.2%) and 40-keV images (sensitivity, 68.8-81.7%) (p = 0.20-> 0.99). However, Image noise was significantly higher at 40 keV, along with greater tumor-to-liver contrast and CNRs for both hepatic parenchyma and tumors (p < 0.01).
Conclusion:
There was no significant difference in hypovascular liver metastases detectability between 70-keV and 40-keV images using the DLIR technology.
More Related Videos
07:47Non-Invasive PET/MR Imaging in an Orthotopic Mouse Model of Hepatocellular Carcinoma
Published on: August 31, 2022
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET